모든 직접 냉각 냉각기 모델

KDS -75℃~200℃
열 프로브
냉각 용량 -40℃@600W
온도 정확도 ±0.2℃

ZLJ & SLJ -150℃ ~ -110℃
초저온 냉각기
냉각 용량 0.4kW~11kW
온도 정확도 ±1℃

MD -75℃~225℃
열 척
난방 및 냉각 -60°C ~ +25°C: 2분 & +25°C ~ -60°C: 6분
온도 정확도 ±0.5℃
전체 방송국 검색
Temp range -150°C ~ -110°C
Utilizing direct cooling system to meet the high-precision temperature control requirements
LNEYA’s direct cooling chiller adopt direct cooling solution, designed for industries requiring rapid heat exchange and ultra-stable temperature management. The direct cooling system can accurately meet the demand for strict temperature control in various industrial applications, ensuring efficiency and stability during the production process.
Direct cooling chiller Descriptions
Through advanced cooling technology, the system can quickly respond to temperature change requirements while maintaining long-term operational reliability, providing you with a better experience and higher production benefits. Our ZLJ series direct cooler utilizes refrigerant direct expansion technology, offering 5X higher heat transfer efficiency compared to traditional liquid cooling methods.
If the model we show (as shown below) does not meet your requirements, please ignore it and contact us. We will tailor it for you according to your needs!
모든 직접 냉각 냉각기 모델
KDS -75℃~200℃
냉각 용량 -40℃@600W
온도 정확도 ±0.2℃
ZLJ & SLJ -150℃ ~ -110℃
냉각 용량 0.4kW~11kW
온도 정확도 ±1℃
MD -75℃~225℃
난방 및 냉각 -60°C ~ +25°C: 2분 & +25°C ~ -60°C: 6분
온도 정확도 ±0.5℃
모델 | ZLTZ-3 ZLTZ-3W |
ZLTZ-6 ZLTZ-6W |
ZLTZ-10 ZLTZ-10W |
ZLTZ-15W | ZLTZ-20W | ZLTZ-30W | ZLTZ-40W | ZLTZ-75W | ZLTZ-100W | ZLTZ-150W | |
온도 제어 | -10℃ ~25℃ | ||||||||||
냉각 용량 | 0℃에서 | 8.1kW | 16.25kW | 28.5kW | 40.2kW | 44.6kW | 70.6kW | 89.2kW | 166.5kW | 215kW | 314.9kW |
10℃에서 | 5.48kW | 11kW | 19.35kW | 26.6kW | 29.8kW | 48.2kW | 59.6kW | 118kW | 147.7kW | 226.6kW | |
11.9 | 23.6 | 41.8 | 58.1 | 70.9 | 106 | 127.8 | 220 | 314.7 | 411.2 | ||
인터페이스 크기 | Drainage outlet | φ12 | φ12 | φ28 | φ28 | φ28 | φ28 | φ42 | DN50 | DN50 | DN65 |
Return water outlet | φ20 | φ20 | φ35 | φ35 | φ42 | φ54 | φ54 | DN80 | DN80 | DN100 | |
수냉식 냉각 | at 25℃ | 2m3/h | 4m3/h | 6.2m3/h | 10m3/h | 12.2m3/h | 19m3/h | 22m3/h | 38m3/h | 54m3/h | 70.5m3/h |
cooling water connector | G3/4 | G1 | DN32 | DN40 | DN40 | DN50 | DN65 | DN80 | DN100 | DN100 |
모델 | ZLTZ4-3 ZLTZ4-3W |
ZLTZ4-6 ZLTZ4-6W |
ZLTZ4-10 ZLTZ4-10W |
ZLTZ4-15W | ZLTZ4-20W | ZLTZ4-30W | ZLTZ4-40W | ZLTZ4-75W | ZLTZ4-100W | ZLTZ4-150W | |
온도 제어 | -40℃ ~20℃ | ||||||||||
냉각 용량 | 10℃에서 | 5.2kW | 11.15kW | 18.4kW | 26.3kW | 31.6kW | 48.2kW | 70.2kW | 124.3kW | 160.4kW | 271.9kW |
20℃에서 | 3.47kW | 7.41kW | 12.3kW | 18.35kW | 21.4kW | 31.4kW | 46kW | 100.1kW | 134kW | 207.8W | |
30℃에서 | 2.24kW | 4.81kW | 7.92kW | 11.8kW | 12.67kW | 19.16kW | 28.2kW | 68.3kW | 90.4kW | 142.3kW | |
40℃에서 | 1.36kW | 2.95kW | 4.7kW | 5.83kW | 6.74kW | 10.45kW | 15.41kW | 42.8kW | 55.2kW | 89.3kW | |
11.55 | 24.5 | 30.4 | 36.1 | 51.4 | 77.9 | 113.9 | 146.1 | 223.4 | 350.8 | ||
인터페이스 크기 | Drainage outlet | φ12 | φ12 | φ16 | φ22 | φ22 | φ28 | φ28 | DN50 | DN50 | DN65 |
Return water outlet | φ22 | φ22 | φ35 | φ35 | φ35 | φ54 | φ54 | DN80 | DN80 | DN100 | |
수냉식 냉각 | at 25℃ | 2m3/h | 4.2m3/h | 5.3m3/h | 6.2m3/h | 9m3/h | 14m3/h | 20m3/h | 31m3/h | 38.5m3/h | 60m3/h |
cooling water connector | G3/4 | G1 | DN32 | DN32 | DN40 | DN50 | DN65 | DN65 | DN80 | DN100 |
모델 | ZLTZ8-3 ZLTZ8-3W |
ZLTZ8-6 ZLTZ8-6W |
ZLTZ8-10 ZLTZ8-10W |
ZLTZ8-15W | ZLTZ8-20W | ZLTZ8-30W | ZLTZ8-40W | ZLTZ8-75W | ZLTZ8-100W | ZLTZ8-150W | |
온도 제어 | -80℃~ -30℃ | ||||||||||
냉각 용량 | 30℃에서 | ||||||||||
40℃에서 | 6.9kW | 14.8kW | 24.4kw | 36.7kW | 42kW | 73.2kW | 110kW | 187.5kW | 257.5kW | 365kW | |
60℃에서 | 3.3kW | 7.1kW | 12kW | 17.4kW | 20kW | 35kW | 52.5kW | 89.3kW | 122.5kW | 173.8kW | |
75℃에서 | 1.65kW | 3.55kW | 6kW | 8.7kW | 10kW | 17.5kW | 26.2kW | 44.7kW | 61.3kW | 87kW | |
인터페이스 크기 | Drainage outlet | φ12 | φ12 | φ16 | φ22 | φ22 | φ28 | φ28 | DN40 | DN40 | DN65 |
Return water outlet | φ22 | φ22 | φ35 | φ35 | φ35 | φ54 | φ54 | DN80 | DN80 | DN100 | |
수냉식 냉각 | at 25℃ | 2.7m3/h | 5.3m3/h | 6.68m3/h | 9.3m3/h | 12.5m3/h | 27.6m3/h | 33.8m3/h | 66.8m3/h | 70m3/h | 125m3/h |
cooling water connector | G3/4 | DN32 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN100 | DN150 |
모델 | ZLJ-41 ZLJ-41W |
ZLJ-43 ZLJ-43W |
ZLJ-46 ZLJ-46W |
온도 범위 | -40℃~-15℃ | ||
온도 제어 정확도 | ±1℃(정상 상태 출구 온도) | ||
냉각 용량AT-35℃ | 0.5kW | 1.6kW | 3.2kW |
냉매 | R404A 옵션 R507C R448 | ||
고온 냉각 | 고온. 150℃ 직접 냉각 기술로 고온에서 빠른 냉각 목표를 달성합니다. | ||
치수 cm | 320*400*600 | 800*700*600 | 450*700*1350 |
회로 차단기 | 6A | 6A | 16A |
모델 | ZLJ-81 ZLJ-81W |
ZLJ-83 ZLJ-83W |
ZLJ-86 ZLJ-86W |
온도 범위 | -80℃~-50℃ | ||
온도 제어 정확도 | ±1℃(정상 상태 출구 온도) | ||
70℃에서 냉각 용량 | 0.4kW | 1.3kW | 2.5kW |
냉매 | R404A/R508B | ||
고온 냉각 | 고온. 150℃ 직접 냉각 기술로 고온에서 빠른 냉각 목표를 달성합니다. | ||
치수 cm | 320*630*650 | 950*1000*800 | 550*1000*1750 |
회로 차단기 | 10A | 16A | 25A |
모델 | SLJ-3W | SLJ-4W | SLJ-6W | SLJ-11W |
온도 범위 | -150℃~-110℃ | |||
냉각 용량 AT-120℃ | 3kW | 4kW | 6kW | 11kW |
냉각 용량 AT-135℃ | 2.5kW | 3.3kW | 5kW | 9kW |
냉매 | LNEYA -150 혼합 냉매 | |||
치수 cm | 750*750*1750 | 750*750*1750 | 950*1000*2050 | 1300*2000*3500 |
회로 차단기 | 40A | 55A | 65A | 100A |
모델 | MD-708 | MD-712 | MDL-708 |
온도 범위 | -75℃~225℃ | -75℃~225℃ | -75℃~225℃ |
온도 제어 정확도 | ±0.5℃(정상 상태 출구 온도) | ||
플레이트 온도 균일성 | ±1℃ | ±1℃ | ±1℃ |
플레이트의 평탄도 | ±15um | ±15um | ±15um |
플레이트 크기 | 직경 200mm 디스크 | 직경 300mm 디스크 | 150mm*200mm |
호스트 및 카드 연결 케이블 | 2.5m(다른 길이는 사용자 지정 가능) | ||
평평한 표면 처리 | 니켈 도금(금도금 옵션) | ||
난방 | -60°C ~ +25°C: 2분 0°C ~ +25°C: 2분 +25°C ~ +220°C: 6분 |
||
냉각 | 220°C ~ +25°C: 2분 +25°C ~ -60°C: 6분 |
||
제어 시스템 | PLC 컨트롤러, 난방 피드포워드 PID 퍼지 알고리즘, 냉각 전자 팽창 밸브 PID 조절 제어 냉각 용량 |
||
표시 및 기록 | 7인치 컬러 터치 스크린, 곡선 온도 및 알람 기록 | ||
커뮤니케이션 | 이더넷 인터페이스, TCP/IP 프로토콜 | ||
압축기 | 테쿰세 | ||
장비 치수mm | 550*650*370 | 550*650*370 | 550*650*370 |
Why Choose LNEYA® direct cooling chiller?
Why Choose LNEYA®?
Global Support & Certifications
Exported to 50+ countries
Trusted by leading labs and manufacturers worldwide
136+ patents
Continuous innovation in low temperature cooler and ultra chiller
30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.
CE 인증, SGS 인증, ISO 인증을 획득했습니다.
포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.
2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.
육안 검사.
성능 테스트.
전기 안전 테스트.