영하 30℃에서 에틸렌 글리콜 냉각기의 설정 및 작동에 대한 소개
The minus 30 degree ethylene glycol chiller is a single-fluid low-temperature refrigeration unit with compressor refrigeration. How should the user set it better when operating it?

1. Automatic logout time
Automatic logout means that when a user has an account and is logged in, the logged-in account will be automatically logged out if there is no operation for a long time.
The working principle of the minus 30℃ethylene glycol chiller is to start timing from the touch screen without operation, and automatically log out and log in when the set value is reached. Each time the touch screen is operated, the timer will be reset to zero. If this parameter has a power-off hold function, the user’s parameters will be retained next time.
2. Language selection
The operating system of the minus 30℃ ethylene glycol chiller currently only supports 2 languages, English and Simplified Chinese. Users can choose according to their language strengths. The language selection has a power-off hold function, that is, the language will be continued at the next power-on. Of course, other languages can also be customized.
3. Buzzer touch response
The buzzer touch response means that when the touch screen is touched, there will be a “di~” sound on the touch screen to prove whether the user’s touch is valid. Users of -30℃ ethylene glycol chiller can cancel this function, and can also prolong the sounding time of this “di~”. Changes to the sound duration require a restart to take effect. This time unit is ms, which is not very accurate due to the limitation of the touch screen clock precision and the processing speed of the processor.
4. Buzzer feedback
Feedback means that the touch screen will produce a pulsed beep sound of “Di Di Di ~”. Because the buzzer power is limited, the sound is not loud, and the volume of the sound cannot be adjusted. If the user of the -30°C glycol chiller intends to use this function and feels that the sound of this function is not enough, an external buzzer can be connected, as explained above.
5. Automatic backlight time
Automatic backlight means that the touch screen will automatically light up when the touch screen is touched, and it will automatically turn off when it is not used for a long time. The touch screen will automatically turn off when it reaches the set time. If it is set to off, the touch screen will always be on. It will have a slight impact on the life of the touch screen of the ethylene glycol refrigerator at minus 30 degrees.
6. System time
The user can modify the system time of the minus 30 degree ethylene glycol refrigerator here. Guanya recommends that the user should not deviate too much from the actual time when modifying, otherwise it will have the possibility of affecting the use of the device. Please do not set a non-existent date (eg: February 30th), which may cause confusion in the device program.
7. Store information
Data logging used for the operation of a -30°C glycol chiller, Users can check the remaining storage space of the touch screen here, and can clean up the disk when the space is low.
8. Temperature save cycle
The touch screen of the minus 30 degree ethylene glycol refrigerator is powered on as a symbol, and it is recorded and saved when it is powered on. Although it will lead to a large amount of useless data, but considering that the storage space is basically sufficient and some users’ requirements for temperature data, the temperature storage cycle is designed. Here you can modify the save cycle of temperature data.
The refrigeration temperature range of minus 30℃ ethylene glycol chiller is from -150℃to -5℃, which can meet the needs of different refrigeration temperatures. It is widely used in low temperature reaction fields in chemical, pharmaceutical, biochemical and other industries.
관련 권장 사항
-
자동차 파워 모듈 냉각 시스템의 작동 파라미터 및 작동 조건 분석
1200선택하기 전에 자동차 전력 모듈 냉각 시스템의 작동 매개 변수 및 작동 조건과 관련된 요인을 알아야 합니다. 그렇다면 어떤 측면에서? 1. 증발 압력 및 증발 온도 작동 중 ...
세부 정보 보기 -
What are the main advantages of oil coolers for the biopharmaceutical industry?
880In the refrigeration system of the oil cooler in the biopharmaceutical industry, the compressor, the evaporator and the condenser are the indispensable parts of the refrigeration system. The condenser is the equipment that emits heat, which combin...
세부 정보 보기 -
Battery test chiller operation evaporating temperature description
1298In the current new energy vehicle battery test equipment, the use of more batteries to test the chiller evaporation temperature has a certain impact on the equipment, then what is the specific impact? When the battery test chiller heat load increa...
세부 정보 보기 -
Analysis of the work and industry application of the chiller
1107Although there are many different types of chillers, most use the same cooling principle. An important part of the process is the coolant or refrigerant, which holds more heat than water and helps maintain an efficient cooling process. Heat is rem...
세부 정보 보기