다양한 고압 반응기 구성을 갖춘 고저온 제어 시스템
Different configurations of high pressure reactors, the quality of products brought by different manufacturers is not the same, but the points of attention are the same, you need to pay attention to it.
1. To be used at the designated location and follow the instructions for use. Check the test pressure, operating pressure, operating temperature and other conditions engraved on the main container, and use it within the allowable range of conditions.
2. The high-pressure reactor is a precision equipment. The sealing ring adopts the form of conical contact and sealing, and the main bolts are tightened to press them against each other to achieve the purpose of sealing. Special care must be taken for the sealing cone to avoid damage caused by various collisions.
When installing the cover, place the reactor body first, then put the cover in a fixed position and install it on the kettle body carefully. When tightening the main bolts, you must tighten them diagonally and symmetrically several times. Evenly, do not allow the kettle cover to tilt to one side to achieve a good sealing effect, and do not exceed the specified tightening torque to prevent the sealing surface from being squeezed or accelerated wear.
3. The pressure used by the pressure gauge of the autoclave should be used within 1/2 of the indicated pressure. And often compare the pressure gauge with the standard pressure gauge and make corrections. The pressure gauge for oxygen should not be mixed with pressure gauges for other gases. For safety valves and other safety devices, use equipment that has undergone regular inspections and meets the specified requirements.
When operating high-pressure reaction kettles with different high and low temperature integrated machine prices, it must be noted that the thermometer should be inserted into the reaction solution accurately. The interior of the autoclave and the gasket should be kept clean. When covering the disc flange cover, the bolts located on the diagonal line should be tightened in turn in pairs. When the measuring instrument is broken, it is mostly broken on the front and rear sides of its glass surface. Therefore, do not stand in these dangerous places during operation. When danger is expected, remove the glass and replace it with a new one.
Pay attention to the same points, but because the brands are different, the products brought are also different, and you need to buy them from regular manufacturers.
관련 권장 사항
-
[Invited to visit] CPHI CHINA 2019, Wuxi Guanya W5P22 booth is looking forward to your arrival!
1260On June 18-20, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 will re-enter Shanghai New International Expo Center. CPhI China World Pharmaceutical Raw Materials China Exhibition is an international, high-qual...
세부 정보 보기 -
Basic Structure of Industrial Water Chiller
1076Basic structure of industrial water chiller:Industrial water chiller consists ofcompressor, condenser, evaporator, expansion valve and other accessories.1. Compressor: in the industrial water chillersystem, the compressor is the power to ensu...
세부 정보 보기 -
초저온 냉장고용 온도 센서
1182초저온 냉장고는 냉동 장비에 사용됩니다. 일반적으로 -60 ° C 이하의 냉동 장비에 사용되며 저온 조건에서 일부 특수 조건에서 사용됩니다. 온도 제어는 매우 중요합니다 ...
세부 정보 보기 -