글리콜 냉각기 누출 검사 시 주의사항
The main points about checking leakage of glycol chiller
During the operation of the glycol chiller, it is critical that the refrigeration system does not leak.

In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy water or other methods. When the refrigeration cycle is in operation, the welds should not be cracked due to vibration, the pipes should not be blocked by debris during welding, and should not enter moisture due to improper operation. When the refrigeration cycle is working, the surface of the welded parts should be clean and clean. No oil stains.
The common leakage points of glycol chillers are evaporator leakage, refrigeration cycle connection leakage, refrigeration cycle valve leakage, compressor pipeline leakage, capillary vibration wear, four-way reversing valve leakage, etc. Common inspections Leakage methods are commonly used in the production and maintenance of refrigeration cycles: visual leak detection, pressure leak detection, instrument leak detection, vacuum leak detection, etc. The user can solve the leakage points one by one.
The fault of leak detection of glycol chiller is relatively common. Therefore, when choosing, it is recommended to choose a fully closed loop piping system and valve parts to choose branded accessories. The evaporator uses a high-power plate heat exchanger, which is small in size, high in efficiency, fast in cooling, safe and reliable, and is used for rapid liquid cooling. It is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.
관련 권장 사항
-
LNEYA 온수기 서큘레이터의 응용 분야
1254온수 순환기, 이것은 매우 좋은 온수기 장치이며 현재 많은 곳에서 사용되고 있습니다. 온수 순환기를 사용하여 사람들은 가정용 온수 사용 문제를 해결할 수 있습니다. 오늘 우리는 온수 순환기의 몇 가지 응용 프로그램을 소개합니다 ...
세부 정보 보기 -
The Instruction Of Ultra Low Temperature Freezer Minus 80 Degrees
1224The machine must be tested before usage (or before it is energized again) in the following conditions: when ultra low temperature freezer is first used in ultra low temperature freezer minus 80 degrees, or after the ultra low temperature freezer i...
세부 정보 보기 -
The main purpose of the ethylene glycol chiller for the heating and cooling unit of the reactor
1225The glycol chiller is suitable forhigh-purity metal, rare substance purification, laboratory environmentsimulation, magnetron sputtering, vacuum coating and other industries. Largecryogenic pump units can provide a cooling environment for labor...
세부 정보 보기 -
Ultra-low temperature bearing cooling equipment Shrink Fit Bearings and Bushings and Pins
1398For the metallurgical industry, the oil pressure system of precision machine tools must use refrigeration to control the oil temperature to stabilize the oil film viscosity so that the machine tool can work normally. If applied to steel products, ...
세부 정보 보기