Principle Analysis of Glycol Chiller
Glycol chiller is an industrial chiller
with glycol as refrigerant. The structure of glycol chiller is roughly the same
as that of ordinary industrial chiller, which is composed of compressor,
evaporator, condenser and electric control system. In order to ensure the
stable operation of glycol chiller, we suggest that you take explosion-proof
measures and buy explosion-proof glycol chiller as far as possible.
1、 Operation of compressor
In order to ensure that the pressure inside
the evaporator is low enough and that the refrigerant is at such a low
temperature, the compressor is used to extract the evaporated refrigerant and
compress the low temperature and low pressure into high temperature and high
pressure refrigerant gas.
2、 Use of condenser
High temperature and high pressure
refrigerant condenses into liquid in the condenser. The refrigerant in the
condenser releases heat in air or water lower than its temperature. Of course,
the temperature of air or water must be lower than that of refrigerant.
3、 How to throttle
After passing through the restrictor, the
refrigerant of the chiller drops from the condensation pressure to the
evaporation pressure, so the liquid from the condenser can be placed in the
liquid reservoir. At this time, the refrigerant is in the state of normal
temperature and high pressure, and then passes through the expansion valve to
reduce the boiling point, enters the evaporator, and the liquid absorbs heat
and evaporates.
4、 Endothermic evaporation
After passing through the restrictor, the
refrigerant liquid with low temperature and low pressure exchanges with the
evaporator, and the absorbed heat becomes saturated or superheated steam.
관련 권장 사항
-
응축 방식에 의한 유기 폐가스 처리
1318유기 폐가스 장비의 응축 처리는 선택 시 성능에 주의를 기울여야 합니다. 유기성 폐가스를 처리하려면 고성능 응축 방법을 선택하는 것이 매우 필요합니다. 그렇다면 유기 폐가스의 사용은 무엇입니까?
세부 정보 보기 -
파워트레인 테스트 냉각 시스템-냉각기 유지보수
1227파워트레인 테스트 냉각 시스템 냉각기는 냉각 시스템 중 하나입니다. 응용 효율이 높고 총 에너지 소비가 낮다는 특징이 있으며 일반적으로 많은 회사에서 선호해 왔습니다. 그러나 어떤 친족이든 ...
세부 정보 보기 -
Professional introduction and application of cooling circulating water machine
1090The cooling water machine (the chiller, also known as the chiller) is an air-cooled water circulation device that does not require a cold water tower. It is a compressor-cooled design that is designed for machines, scientific instruments, or produ...
세부 정보 보기 -
난방 및 냉방 순환 수조를 선택하는 방법은 무엇인가요?
1415난방 및 재순환 수조 선택 과정에서 난방 전력, 냉방 전력, 압력 및 유량도 사용자가 고려해야 할 요소입니다. 좋은 시스템 설계 및 액세서리 브랜드 선택은 전체 난방 및 냉방과 관련이 있습니다.
세부 정보 보기