What are the characteristics and application scope of cryogenic refrigeration circulators?
Specializing in the development and production of low-temperature refrigeration circulators, the refrigeration temperature range is from -120 degrees to -30 degrees. Today, let us take a look at the characteristics of low-temperature refrigeration circulators.
Features of low temperature refrigeration circulator:
1. To save water resources, you can use a mixture of glycol and water for refrigeration cycle, saving resources, strict circulation pipeline design, preventing circulating water pollution and extending the use time of circulating water
2. Multi-protection operation is more reliable
3. 브랜드 컴프레서, 캐스케이드 과냉각 냉동 기술 채택
4. Humanized design, flexible and more convenient
5. Double condensing high-efficiency system
6. Computer cascade temperature controller, temperature digital display, adjustment unit 0.1 degree, PT100 temperature sensor, temperature control range -120~30℃
7. Using super-cooling technology to ensure temperature stability at low temperatures
8. The temperature difference between turning on the compressor and turning off the compressor can be set
9. Ambient temperature monitoring function to prevent excessively high system operating environment temperature
10. Power-on delay protection, three-level cascade system protector
11. All parts are fully grounded
12. Fully enclosed design, no water absorption during low temperature operation, to ensure the purity of the cold heat transfer medium, prevent ice crystals, and improve the life of the heat transfer fluid
13. High-performance circulating pump can ensure continuous operation for 24 hours a day
14. Adopt plate cold heat exchanger to improve heat exchange efficiency
Application range of low temperature refrigeration circulator:
1. Cooling of heat-generating parts of semiconductor manufacturing equipment
2. Cooling of the heating part of the laser device
3. Cooling of heat generating parts of other industrial equipment
4. Analyze and test the cooling of the heating part of the machine
Structure analysis of low temperature refrigeration circulator:
Control panel: display set temperature and measured temperature touch key operation to input temperature
Slotted temperature control, no notch on the top, stainless steel high temperature reaction tank
Brand compressors, all compressors are selected imported brands, high efficiency
Electrical cabinet: The electrical cabinet has clear lines and compact structure
Liquid inlet and outlet interface: provide standard interface size, stainless steel material, anti-rust
Circulating pump: powerful circulating pump to ensure the delivery of high-viscosity liquids
Regular inspection and maintenance:
That is to say, the ultra-low temperature refrigeration cycle machine should be checked and maintained for a long time, and the operation should be started on time to avoid unavoidable problems such as oxidation of the water pump, compressor and related components due to prolonged non-operation.
관련 권장 사항
-
저온 냉각기 유지 관리 방법
1032저온 냉각기는 많은 산업 생산 작업에서 사용해야하는 일종의 냉동 기계 장비입니다. 그것은 다양한 생산 작업에 매우 우수한 냉동 기술을 제공하고 원활한 진행을 보장 할 수 있습니다 ...
세부 정보 보기 -
반도체 디바이스 테스트 장비는 어떤 산업에서 사용되나요?
1200반도체 소자 테스트 장비는 반도체 산업에서 더 많이 사용됩니다. 그렇다면 해당 반도체 도체에 대해 얼마나 알고 계십니까? 이 물질의 특성은 여전히 사용자에게 권장됩니다. 일반적으로 물질은 ...
세부 정보 보기 -
LNEYA 칩 테스트 온도 제어 시스템 운영 개요
1449기술의 발달로 칩 테스트는 특정 온도 요건 하에서 정확도에 대한 요구 사항이 매우 높아졌습니다. 그렇다면 칩 테스트 시스템에 대한 이해는 어떻게 될까요? 칩 테스트는 저온에서 높은 온도 정확도가 필요합니다.
세부 정보 보기 -
How to maintain and extend the service life of the dynamic temperature control system?
1005Dynamic temperature control system is a fully enclosed refrigeration and heating temperature control device that provides cold and heat sources. The service life is related to the usual maintenance and cleaning. Dynamic temperature control system...
세부 정보 보기