Powertrain test cooling system-the maintenance method of the chiller:
1.Screw compressor
Screw compressor is a very important component in the unit. The advantages and disadvantages of refrigeration compressors are immediately related to the reliability of the unit.
2. Check the valve
Powertrain test cooling system-the condenser of the freezer and the evaporator of the air conditioner are both classified as high-pressure vessels. According to requirements, valves must be installed on the high pressure end of the unit, that is, the condenser itself. Once the unit is in an abnormal office environment , The valve can automatically relieve pressure to avoid high pressure that is likely to cause damage to the body. Therefore, the valve’s on-time calibration is very important for the reliability coefficient of a unit.
3. The addition of refrigerant
If there is no other unique reason, the general unit is not easy to cause a lot of leakage. If a certain amount of refrigerant leaks due to incorrect operation or after maintenance, it is necessary to add refrigerant again. When adding refrigerant, pay attention to the type of refrigerant used by the unit.
4. Disassembly and replacement of dry filter device
The dry filter device is a key component to ensure that the refrigerant develops all normal circulation systems. Because water and refrigerant are miscible with each other, if the system software contains water, it will greatly harm the operating efficiency of the unit. Therefore, it is very important to maintain the dryness of the system software. The filter element inside the dryness filter device must be removed on time. change.
5.Dismantle and replace the grease
Powertrain Test Cooling System-After long-term application of the chiller, the oil quality of the grease will decrease, and the residue and moisture inside the oil will increase, which will harm the actual cooling effect of the cooling system group. Therefore, it is necessary to observe and inspect the oil on time Product. Once a problem is found, it should be replaced immediately, and the grease type to be replaced must conform to the technical documentation.
6. Cleaning of condenser and air-conditioning evaporator
Because the cooling water of the water cooler condenser is an open circulatory system control loop, the drinking water is generally used in the circulatory system of the glass fiber reinforced plastic cooling tower. When the calcium and magnesium salts in the water are very large, they are very easy to dissolve and accumulate on the cooling water pipe to produce dirt and harm the actual effect of heat transfer. Excessive fouling will continue to reduce the commercial circulation cross-section of the cooling water, reduce the water flow, and increase the working pressure. Therefore, when the water body of the applied cooling water is weak, the cooling water pipe is cleaned less once a year to remove the dirt and waste in the pipe.
관련 권장 사항
-
암모니아 냉동 시스템에서 산업용 냉각기의 배출 작동 단계
1095The rubber hose used to connect the outlet valve joint causes one end to be inserted into the water of the water container. When the ammonia in the mixed gas is cooled into ammonia liquid, the bottom of the air separator will frost. At this time, ...
세부 정보 보기 -
고출력 산업용 냉장고 증발기 유지보수 주의사항
1100고출력 산업용 냉장고는 산업용 저온 가공에 사용됩니다. 고출력 산업용 냉장고의 증발기는 가장 중요한 구성 요소 중 하나이며 고출력 산업용 냉동기의 냉각 효과에 영향을 미치는 요소 중 하나입니다....
세부 정보 보기 -
What to do When the High Pressure Alarm of the Chiller?
1358People must pay attention to the maintenance of large-scale temperature control equipment such as industrial water chiller. Sometimes it is normal to encounter high-pressure alarm. We must first find out the causes of high-pressure of the industri...
세부 정보 보기 -
The Inevitable Development Of New Energy Vehicle Battery Test Cooling Device
916New energy vehicle battery test cooling device The energy crisis and environmental pollution have spawned the development of new energy vehicles. The key to the technology of new energy vehicles is the performance of power batteries. There are man...
세부 정보 보기