다양한 주변 온도에서의 배터리 충전 테스트 조건
At present, the battery is undoubtedly the most core and critical component in electric vehicles. Therefore, both the OEM and the battery factory need to conduct a comprehensive test of the battery. The characteristics of automotive lithium-ion power batteries are greatly affected by ambient temperature. In low temperature environment, the available energy and power attenuation is more serious, because long-term charging in low temperature environment, the life will be greatly shortened.
In the case of -10 degrees, the battery capacity and operating voltage are significantly reduced; in the case of -20 degrees, the discharge capacity decreases sharply, and the specific capacity is only about 30% of that at normal temperature. Charging at low temperatures is also difficult. Metal lithium formed on the surface of the negative electrode is easy to accumulate. Further chemical reactions will cause internal short circuits in the battery, greatly reducing safety. In the measured temperature range, the internal resistance of the battery is higher under low temperature conditions, and the internal resistance becomes lower and lower as the temperature increases. The change of discharge energy is basically opposite to the change of internal resistance.
According to authoritative tests, the battery charging start current in hot cars is higher than cold cars, and the charging current is higher than cold cars, because the charging voltage is significantly higher than cold cars.
In these tests, the accuracy and temperature simulation become a very important factor. LNEYA’s KRY series-battery motor test cooling heating system is a product born for this emerging field. Fully enclosed tube design, high-efficiency plate heat exchanger, used for lifting temperature and constant temperature control in the test of new energy batteries and motors, especially suitable for heat dissipation and heat release process control during the test. With automatic fault protection function, it can output corresponding signals to ensure equipment safety. The main parts are international brands, quality assurance, the surface is treated with high-voltage electrostatic spraying, and auxiliary equipment can be added according to specific needs. It can achieve multi-channel temperature and flow control, one device can achieve multi-channel output, and each channel can control different flows without interfering with each other. Accepting customization requires solutions that control different flows and temperatures simultaneously.
관련 권장 사항
-
SUNDI Cooling And Heating System-R & D testing of organic synthetic materials and fine chemicals
1279LNEYA's customer is a research institute engaged in the research, development and production of high-performance, environmentally-friendly new organic materials and fine chemicals.The adhesives produced by customers can be used in integrated circu...
세부 정보 보기 -
에나멜 리액터를 사용하는 것이 왜 위험한가요?
1289에나멜 반응 주전자의 에나멜 층은 차갑고 뜨거울 때 파열되기 쉽습니다. 에나멜 층은 에나멜 반응 주전자의 표면에 소결되고 섭씨 200도를 초과하면 에나멜 층이 녹기 때문에 에나멜 층이 녹기 때문에 ...
세부 정보 보기 -
VOCS 응축 흡착기 공명 결함 설명 정보
1159보컬 응축 흡착기를 선택할 때 LNEYA는 간단한 결함을 피하기 위해 신뢰할 수있는 보컬 응축 흡착기 장비를 선택할 것을 권장하지만 유사한 공명 결함이 발생하면 제때 해결해야합니다. VOCS 가의 경우 ...
세부 정보 보기 -
Cooling and heating temperature control equipment for liquid distribution system
925The cooling and heating temperature control equipment of the liquid distribution system is a dynamic temperature control system produced by LNEYA. When we purchase the cooling and heating temperature control system of the liquid distribution s...
세부 정보 보기