전기 자동차 배터리 테스트 드라이버를 접지하는 방법은 무엇인가요?
The electric vehicle battery test is in the running state, and it is necessary to understand the operation of the accessories, and the drive and other accessories are in operation.
If the electric vehicle battery test is not isolated between the AC power source and the drive DC bus (such as a transformer), do not connect the non-isolated port of the DC bus or the ground of the non-isolated signal to the ground, which may result in equipment damage and personal injury. Because the common voltage of the AC is not earth-proof, there may be a high voltage between the DC bus ground and the earth.
In most electric vehicle battery test systems, all common ground and earth are connected together at the signal end. A variety of ground loops generated by grounding are susceptible to noise and generate flow at different reference points.
In order to keep the command reference voltage constant, the signal ground of the driver is connected to the signal ground of the controller, which is also connected to the ground of the external power supply, which will affect the operation of the controller and the driver.
It is difficult to test the grounding of the shield layer of the electric vehicle battery. There are several methods. The correct shielding grounding is at the reference potential point inside the circuit. This point depends on whether the noise source and the receiving are grounded at the same time, or floating. Make sure that the shield is grounded at the same point so that ground current does not flow through the shield.
For the electric vehicle battery test to maintain a stable operating state, it is necessary to understand the operation of the above accessories.

관련 권장 사항
-
How To Reduce Operating Costs For Electric Vehicle Power Battery Testing Equipment?
1038Since many harsh environments easily affect the operating power of electric vehicle power battery testing equipment, in order to ensure the safety of equipment operation, enterprises need to choose a suitable safety environment when installing ele...
세부 정보 보기 -
화학 산업에서 산업용 냉각기의 디버깅 단계
1119After completing the installation ofindustrial water chillers in chemical enterprises, certain debugging needs tobe carried out in the early stage ofoperation. Only through careful debugging can we find out whether there arehidden troubles in...
세부 정보 보기 -
순환 유체 온도 제어 장치의 보호 장치 세부 정보
1200순환 펌프 과부하 보호 기능은 순환 액체 온도 조절 장치가 너무 클 때 순환 펌프의 주 전원을 차단하는 기능입니다. 재설정 시 녹색 버튼을 누르고 빨간색 버튼은 정지 버튼입니다...
세부 정보 보기 -
추출 및 분리에서 고온 및 저온 순환 장비를 사용하는 방법은 무엇입니까?
908과학과 기술의 지속적인 발전으로 고온 및 저온 사이클 산업용 온도 제어 장비는 많은 분야, 특히 추출 및 분리 분야에서 중요한 역할을 합니다. 이 기사는 ...
세부 정보 보기