초저온 냉각기 기능
The ultra low temp chiller is controlled by microcomputer, and the refrigeration compressor and its system components are energy-saving products, which greatly improves the reliability of the whole machine. The unit can realize multi-stage energy automatic adjustment operation according to the load requirements, and the temperature accuracy can be accurately controlled to plus or minus 0.001 degrees. Effective management of temperature rates and slopes can be achieved. Ultra low temp chiller is a unit with a temperature of -128 degrees Celsius.
Ultra low temp chiller is energy efficient, the comprehensive energy efficiency ratio is up to 8.0, and it can provide refrigeration, heating, and domestic hot water. It can be fully switched according to the ambient temperature and hot water demand, making full use of energy. Safe and environmentally friendly, with refrigerant as the medium, non-toxic, no explosion hazard, can be connected to the original hot water system. It can replace the high-risk, high-cost boiler system, can also be used in conjunction with the solar system, replacing the electric heating part. Fully automatic computer control, no need for special monitoring, can be operated by remote or centralized management system.
1. The ultra low temp chiller has a large compression ratio requirement with respect to the compressor, so that most of the deep-cooling field adopts a more complex cascading compression or secondary compression than a single compressor on the system.
2. The ultra low temp chiller runs smoothly and reliably, which is not easy to damage, and has low noise. Since the compressor lubricating oil is supplied by high and low pressure difference, the built-in oil of the compressor has a high oil separation efficiency. It can also absorb the noise of the unit.
3. Ultra low temp chiller built-in large volume capacity snow storage tank to ensure sufficient snow, set up multiple plate heat exchanger to ensure sufficient heat transfer power, set up gas-liquid separator at the end of the refrigeration return for gas-liquid separation to ensure no liquid Entering the compressor causes the connecting rod to break, preventing the compressor from being scrapped.
관련 권장 사항
-
Miniature high-pressure reaction kettle refrigeration heating temperature control system
1037The miniature high-pressure reaction kettle refrigeration heating temperature control system is designed with a gas feed unit, a liquid feed unit, a reaction unit and a collection unit. The raw material gas and raw material liquid are mixed and pr...
세부 정보 보기 -
Circulating Chiller for 100 mL Laboratory Reactor
747When choosing the right circulating chiller for your 100 mL laboratory reactor, there are several factors to consider to ensure that the equipment can provide precise temperature control and efficient cooling. ...
세부 정보 보기 -
Laboratory Polymerization Reactor Water Cooling Chiller
798Laboratory Polymerization Reactor Water Cooling Chiller is a device used to accurately control the temperature inside the reactor, especially for polymerization reactions that need to be carried out under specific temperature condition...
세부 정보 보기 -
직접 접촉식 액체 냉각과 냉각판 액체 냉각 기술의 차이점
1289냉각판 액체 냉각 기술은 가열 부품의 열을 냉각판을 통해 순환 파이프 라인에 둘러싸인 냉각 액체에 간접적으로 전달하고 열을 ...
세부 정보 보기