-20 ° C freezer manufacturers choose what to look at the evaporator?
In the process of producing industrial freezer, the selection of a suitable evaporator is also very important for the freezer, because the choice of suitable evaporator is better for better operation of the -20 °C freezer.
The evaporator is generally equipped with a -20 °C freezer, and the user does not have to choose. However, in order to better maintain the refrigeration system and ensure its efficient operation, some factors should be noted. Due to the influence of the height of the refrigerant liquid column of the -20 °C freezer manufacturer, the evaporation temperature at the bottom of the full liquid evaporator is higher than the evaporation temperature of the liquid surface. Different refrigerants have different effects on the evaporating temperature of different liquid levels due to the height of the hydrostatic fluid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the effect of the hydrostatic height on the evaporation temperature. Therefore, the effect of the hydrostatic height on the evaporation temperature can be ignored only when the evaporation pressure is high. When the evaporation temperature is low, it cannot be ignored. That is to say, it is uneconomical to use a full liquid evaporator at this time.
If the -20 ° C freezer evaporating temperature is lower than the brine solidification temperature, the brine may freeze. In one process of the brine, the temperature of the brine is low and the possibility of freezing is relatively large. When water is used as the brine, it is theoretically possible that the inner wall temperature of the tube can be as low as 0 °C. However, for safety reasons, the inner wall temperature of the tube at the outlet end of a process is usually maintained above 0.5 °C. In the case of brine as a coolant, according to the same principle, the inner wall temperature of the pipe should be higher than the solidification temperature of the brine by more than 1 °C.
When the -20 °C freezer refrigerant flows through the evaporator, the pressure loss is caused, and the pressure p2 of the refrigerant at the outlet of the evaporator is inevitably lower than the pressure p1 at the inlet, thereby lowering the suction pressure of the compressor, resulting in a decrease in the refrigeration capacity. According to different models, the choice of evaporator is different, such as box type freezer, using water tank coil evaporator; open type freezer and screw type freezer, use shell and tube evaporator; Acid-base freezer, you can choose titanium tube evaporator or stainless steel plate exchanger, of course, can be customized according to user needs.
In general, manufacturers have certain principles in selecting evaporators. Basically, brand evaporators are one of the manufacturers’ choices.

관련 권장 사항
-
열전달 오일 순환 시스템의 냉각 성능 저하 문제를 해결하는 방법은 무엇입니까?
1145일부 열 전도성 오일 순환 시스템은 3개월 사용 후 이전만큼 좋지 않을 수 있습니다. 이때 전문 애프터 서비스 부서에 연락하여 사용자의 전원 공급 장치와 장비가 정상인지 확인하는 것이 좋습니다.
세부 정보 보기 -
Instructions for use of the enclosed cooling and heating circulator of LNEYA, a chiller manufacturer
961In the chemical and pharmaceutical field,the closed cooling and heating circulator is a cooling and heating temperaturecontrol device that cooperates with various types of reactors, jacketed tanks,reactors, extraction equipment and other equipm...
세부 정보 보기 -
CIPM China [C-48-2]는 신규 및 기존 고객을 환영합니다!
1342제58회(2019년 가을) 전국 제약 기계 및 중국 국제 제약 기계 박람회가 2019년 11월 5일부터 11월 7일까지 충칭 국제 엑스포 센터에서 개최됩니다. 그것은 업계에서 교수로 인정 받고 있습니다 ...
세부 정보 보기 -
Maintenance of high and low temperature circulator in the pharmaceutical industry
954The high and low temperature circulator in the pharmaceutical industry is also an increasingly common temperature control equipment in all walks of life. It is inevitable that the equipment needs to be maintained after long-term use. How to mainta...
세부 정보 보기