Instructions to Use Industrial Cryogenic Refrigerator
Industrial refrigerators are one of the cold water machines. It is classified according to the cooling mode of the cold water machine itself. It is divided into air cooling type refrigerators and water cooled refrigerators.
Structural features: a standard refrigerator freezer is composed of a compressor, condenser, evaporator, filter drier, expansion throttling valve of the five most series, note the amount of refrigerant inside (refrigerant), the electrical appliances (including controller) according to the requirement of the environment and control the operation of the compressor to achieve the purpose of heat transfer and refrigeration.
With the progress of the society, the industry has also been developed rapidly. Today, we will discuss the use of the laboratory refrigerator (industrial refrigerator).
1. Always check the sealing strip of the outer door.
2. Place it firmly and horizontally on the ground when carrying.
3. Clean the filter once a month (use a vacuum cleaner to suck, rinse it with water, finally dry and reset the filter), and suck the dust on the internal condenser with a vacuum cleaner in every two months.

4. When defrosting, you should cut off the power and open the door. When the ice and cream begin to melt, put in each layer of the refrigerator clean and bibulous cloth.
5. Clean it every month to make sure it is clean.
6. Remove the small amount of the dustin the fridge on the internal and external and accessories with dry cloth. If the fridge is too dirty, use neutral detergent and wash thoroughly with clean water after washing. Do not rinse the inside and upside of the refrigerator with water, otherwise, it will damage the insulation and cause failure.
7. Don’t put the lubricating oil to the compressor and other mechanical parts.
8. Take care when cleaning the fans in the back of the compressor.
9. The maintenance and maintenance of cryogenic refrigerator is particularly important to extend the life and the normal use. If the temperature control is not accurate, it often leads to damage the saved objects which will cause great influence to the experimental results, thus affecting the normal work.
관련 권장 사항
-
Part of LNEYA Equipment Function Introduction
13981.1.1 The industrial chillers(SUNDI series) is applied to cooling and heating the reactor, especially suitable for the process of heating and exothermic process. It can control the material temperature in the reactor, can choose the program contro...
세부 정보 보기 -
소형 수냉식 냉각기가 냉매를 충전할 때 따라야 하는 방법
1187우리 생활에서 누구나 냉방에 매우 익숙하다고 생각합니다. 중앙 공조 및 산업 생산 공정 냉각 산업에서는 소형 수냉식 냉각기가 더 일반적입니다. 이 장치는 압축기로 구성됩니다 ...
세부 정보 보기 -
The main purpose of the reactor heating and cooling system
1198The reaction kettle heating and cooling system is suitable for high-purity metals, rare substance purification, laboratory environment simulation, magnetron sputtering, vacuum coating and other industries. The large-scale cryogenic pump unit can p...
세부 정보 보기 -
Refrigerating Output of Low Temperature Cooling Circulator
948The refrigerating output of low temperature cooling circulator varies with different working conditions. So, when the process calculation is carried out at the beginning, it is necessary to set an allowance for the refrigerating output of the heat...
세부 정보 보기