How to deal with organic waste gas treatment refrigerant leakage?
In the process of organic waste gas treatment, if it is found that the refrigerant leaks, it is recommended to treat it in time. LNEYA organic waste gas treatment professional manufacturer then analyzes the knowledge of organic waste gas treatment refrigerant leakage.
Organic waste gas treatment VOCS gas single material or multi-material condensation recovery, the main treatment gases are: hydrocarbons such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, Styrene, naphtha, etc.; alcohols, ethers, ketones, esters, etc., in the event of a situation, we must now fill the leak or treatment of the refrigerant leakage, then replace the desiccant, re-vacuum treatment, Fill the appropriate refrigerant. When you find that the leaking refrigerant is partially immersed in water, stop the chiller and quickly remove the water from the tank to prevent the compressor from drawing water into the system for more serious damage.

So, what should be done if the organic waste gas treatment refrigerant is found to be insufficient? Organic waste gas treatment failure phenomenon: the whole vehicle refrigeration effect is poor, the air outlet air is only cool, and the manifold pressure gauge check finds that the high pressure is cut and the low pressure side pressure is low (when the compressor speed is 2000/mim, the ambient temperature is about 35C). The low pressure gauge index is lower than 1kg/CM square, the high pressure gauge index is lower than 10kg/CM square, and the bubble flow is visible from the sight glass.
This may be due to a refrigerant leak point in the refrigeration system, resulting in insufficient refrigerant. Treatment method Use an electronic leak detector to detect the leak point and carry out the replacement or replacement of parts. If the parts are not replaced, only the appropriate amount of refrigerant can be replenished; if the parts are replaced, the appropriate amount of refrigerating oil should be added as required, and the refrigerant should be added after the system is vacuumed.
The above is the relevant treatment of organic waste gas treatment refrigerant leakage. If the Wuxi LNEYA organic waste gas treatment equipment fails, it is recommended to solve it in time!
관련 권장 사항
-
How to deal with the malfunction of Industrial Water Chiller System?
1223What's wrong with the Industrial Water Chiller System when it fails to cool down? Let LNEYA explain it to you below: One reason is that the initial use of liquid chiller system fails to reduce the temperature, or there is something wrong with ...
세부 정보 보기 -
파워트레인 테스트 냉각 시스템-냉각기 유지보수
1227파워트레인 테스트 냉각 시스템 냉각기는 냉각 시스템 중 하나입니다. 응용 효율이 높고 총 에너지 소비가 낮다는 특징이 있으며 일반적으로 많은 회사에서 선호해 왔습니다. 그러나 어떤 친족이든 ...
세부 정보 보기 -
Application Of Jacketed Reactor Cooling And Heating System In Chemical Reactions
1089In the chemical industry, jacketed reactor cooling and heating devices are widely used in various chemical reactions. Application of jacketed reactor cooling and heating devices in various chemical reactions: Polymerization is a c...
세부 정보 보기 -
저온 산업에서 열악한 냉동 성능과 냉매의 관계
942저온 산업용 냉장고의 냉동 시스템의 효과는 냉매와 직접적인 관련이 있습니다. 냉매가 누출되면 냉각 용량이 충분하지 않으므로 흡입 및 배기 압력이 상대적으로 ...
세부 정보 보기