난방 및 냉방 순환 수조를 선택하는 방법은 무엇인가요?
Heating and recirculating water bath In the process of selection, heating power, cooling power, pressure and flow are also factors that users need to consider. Good system design and accessory brand selection are related to the whole heating and cooling cycle water bath selection.
As far as the heat transfer medium of the heating and cooling cycle water bath is concerned, water is used as a heat transfer medium, which is economical and environmentally friendly. Even if a leak occurs, it can be directly discharged without polluting the environment, but the water easily causes corrosion and scaling of the water tank and the flow path. In addition to anti-corrosion agent pretreatment, it should be periodically derusted during use. The heat transfer oil is used as the heat transfer medium, and the thermal conductivity is only 1/3 of water, the cost is relatively high, and it is easy to coke. Special application environments are also factors to consider when choosing a temperature machine.

The realization of the temperature control of the heating and cooling cycle water bath is based on the control of the temperature of the hot fluid, the temperature control based on the temperature of the reactor, and the combined temperature control. The user should investigate the implementation of the operation according to the actual situation and select the fluid that can meet the accuracy requirements of his own temperature control. Based on the temperature control of the hot fluid, the temperature displayed on the control panel and the temperature of the device are inconsistent. Since the injection cycle, injection speed, melting temperature and ambient temperature are not compensated, the temperature fluctuation of the reactor is relatively large. Temperature control based on hot fluid can meet most of the requirements and is a common method. The temperature control based on the temperature of the reactor is installed in the interior of the reactor by a temperature sensor, and is set on the control panel to show that the temperature of the temperature reactor is uniform, which is suitable for the case where the temperature control precision is high.
When the user operates the heating and cooling cycle water bath, the high-efficiency equipment can continuously stabilize the reaction process, and the temperature control accuracy is plus or minus 1 degree, which can be dynamically controlled.
관련 권장 사항
-
대형 급속 냉동고 압축기의 냉각 문제를 해결하는 방법은 무엇입니까?
1450대형 급속 냉동고에는 여러 종류의 압축기가 있으며 모델에 따라 압축기의 브랜드와 모델이 다릅니다. 압축기 온도가 너무 높으면 일부 고장이 발생할 수 있으므로 냉각도 ...
세부 정보 보기 -
Methods for Chiller Manufacturers to Ensure Product Quality
1030Before producing the industrial chiller, the chiller manufacturer will consider the applicable industry, refrigeration capacity, structure, etc., and consider the actual use environment during design and assembly to optimize some functions. In ord...
세부 정보 보기 -
사출 성형기용 윤활유를 선택하는 방법은 무엇입니까?
1421사출 성형기 냉각 시스템 윤활유는 선택할 때 압축기 유형에주의를 기울여야합니다. 압축기에는 피스톤 유형, 스크류 유형 및 원심 유형의 세 가지 유형이 있습니다. 처음 두 종류의 윤활유는 ...
세부 정보 보기 -
반도체 냉장 온도 제어 시스템 선택 지침
1449반도체 냉동 온도 제어 시스템의 선택은 저온 부하와 고려해야 할 사항을 기반으로해야합니다. 저부하 작동으로 작동 조건이 긴 냉동 시스템의 경우 다중 ...
세부 정보 보기