고온 및 저온 충격 시험 챔버의 작동 원리 설명
Spot high and low temperature impact test chamber, also known as three-box high and low temperature impact test chamber, high and low temperature impact test chamber is mainly composed of low temperature storage chamber, high temperature storage chamber and impact temperature test chamber. Knowing how it works, plays a vital role in how to operate scientifically and how to protect it properly.
1. High-temperature storage room: The central controller detects the instantaneous signal from the temperature-sensing component, compares it with the set temperature signal, and obtains the comparison signal. The time-regulated heating of the solid-state relay is controlled by the output signal of the instrument PID logic circuit. The output power is sized to achieve automatic temperature control.
2. Low-temperature storage room: The temperature state of the spot high-low temperature impact test box is determined by the working state of the heater, evaporator and fan in the air duct. After the refrigerant flowing out through the expansion valve enters the evaporator in the working chamber, the heat in the working chamber is absorbed and vaporized, so that the temperature of the working chamber is lowered; the working fluid after gasification is sucked by the compressor and compressed into high temperature and high pressure gas into the condenser. The medium is condensed into a liquid, and after being screened, it is throttled by the expansion valve, and then again enters the evaporator of the working chamber to absorb heat and vaporize and then is sucked and compressed by the compressor. This reciprocating loop works to bring the studio temperature down to the set temperature requirement.
3. Impact temperature test room: Automatically control high and low temperature gas valve by spot high and low temperature impact test box instrument, switch between low temperature or high temperature storage room, form closed circuit air circulation system with high temperature box or low temperature box respectively, and quickly reach the test target temperature. The temperature state in the test chamber is determined by the operating conditions of the heater, evaporator, and fan in the duct. The working chamber of the test box adopts the forced axial flow “scattering” type loop wind operation, which can greatly improve the parameters such as fluctuation and uniformity of equipment operation.
After understanding the principle of use, the high and low temperature impact test chamber also needs regular maintenance to improve its efficiency.

관련 권장 사항
-
Refrigeration effect of water-cooled chiller at -15℃
913The main configurations of water-cooledchillers are: compressors, electrical components, water pumps, evaporators,condensers, high/low pressure controllers, high/low pressure gauges, LCDthermostats, expansion valves, antifreeze switches, hand v...
세부 정보 보기 -
Application Note of Low Temperature Refrigerator for Cold Shrink Assembly of Automobile Engine Parts
1242Engine assembly is carried out in a low-temperature environment below minus 30°C in a low-temperature refrigerator. The mainstream automobile engine manufacturers have their own low-temperature assembly workshops. Engines assembled in a low-temper...
세부 정보 보기 -
소형 수냉식 냉각기가 냉매를 충전할 때 따라야 하는 방법
1194우리 생활에서 누구나 냉방에 매우 익숙하다고 생각합니다. 중앙 공조 및 산업 생산 공정 냉각 산업에서는 소형 수냉식 냉각기가 더 일반적입니다. 이 장치는 압축기로 구성됩니다 ...
세부 정보 보기 -
Chip temperature control device detection application technology
1166The chip temperature control device is mainly used in the field of chip testing. For different types of chip types, the detection technology also needs attention, so it is necessary to pay attention to the practical application of different detect...
세부 정보 보기