Glycol chiller installation requirements
In the summer, the use of glycol chillers is relatively frequent. Efficient glycol chillers are also needed. Therefore, when installing glycol chillers, they need to be installed on a smooth and tidy floor. Why choose a smooth ground when installing? Users who have known the glycol chiller should know that if the glycol chiller is tilted during installation, it may cause the refrigerant or cooling water or chilled water to operate abnormally, and the refrigerant may flow backward or the resistance may increase, which is not conducive to The normal operation of the refrigeration system, therefore, the glycol chiller needs to operate on a stable ground.
The glycol chiller can run the compressor on a stable surface to make the compressor run more efficiently. Because the normal operation of each component of the compressor takes into account the gravity problem, the smooth ground can avoid the resistance of the liquid medium in the flow or the acceleration of gravity, and the glycol chiller can be operated more efficiently.
Of course, the noise problem is also plaguing many users of glycol chillers. In fact, the flat ground can effectively reduce the vibration and noise during operation, because the flat ground can reduce the vibration during operation, which is beneficial to its ethylene glycol. Silence effect to enhance its service life.
If the glycol chiller is operated on a non-flat floor, due to the effect of gravity, the probability of loosening and peeling off under the vibration generated by the operation of the glycol chiller is greater.
The installation of the glycol chiller must be carried out on a stable floor. This is relatively simple, and the user can install it according to the requirements.

관련 권장 사항
-
저온 냉각기 서큘레이터의 스크류 컴프레서에 대한 냉동 설명
1246컴프레서가 다르기 때문에 저온 냉각기 서큘레이터의 성능도 다릅니다. 스크류 컴프레서는 피스톤 컴프레서와 다르며 구조가 더 정밀합니다. 따라서 사용자가 선택해야하는 경우 ...
세부 정보 보기 -
40GW 극저온 냉각기의 유형 선택 및 분류에 대한 설명
1194If different enterprises and different industries have different requirements for Wuxi Guanya 40GW cryogenic chillers, its model selection is also different. So it is better to have a clear understanding of the needs of the selection of 40GW cryog...
세부 정보 보기 -
Pharmaceutical WFI system low-temperature cooling water circulator/chiller
881The WFI (Water for Injection) system in the pharmaceutical industry is a highly purified water system that provides sterile water that meets strict quality standards for drug production and formulations (such as injections). ...
세부 정보 보기 -
소형 온도 제어 시스템 장비 용접 유지보수 주의사항
1177소형 서모 스탯 제어 시스템 장비는 수리시 비교 지점에주의를 기울이고, LNEYA 전문 제조업체는 용접 부분도 유지 보수의 핵심 포인트 중 하나라고 상기시킨 다음 어떤 측면에주의를 기울여야하는지 상기 시켰습니다 ...
세부 정보 보기