The reason why the semiconductor small thermostat is blocked by refrigeration
The small semiconductor small-scale thermostat ice jam is mainly caused by the excessive moisture contained in the refrigeration system. With the continuous circulation of the refrigerant, the moisture in the refrigeration system gradually collects at the capillary outlet, in view of the relatively low temperature at the capillary outlet, the water It forms ice and gradually increases. When it reaches the necessary level, the capillary is completely blocked, the refrigerant does not recur, and the semiconductor small thermostat does not cool.
The main reason for the moisture in the small semiconductor small-scale thermostat refrigeration system is that the electromechanical insulation paper in the compressor contains water, which is the main source of moisture in the system. In addition, the residual moisture of the components of the refrigeration system and the combined pipelines due to insufficient drying; the refrigeration oil and the refrigerant contain more than the allowable amount of moisture; during the installation or maintenance process, the pipeline is in a state of development for a long time, causing moisture in the air to be Inhaled by electromechanical insulation paper and refrigerating machine oil.

In view of the fact that the above causes the water content of the refrigeration system to exceed the allowable amount of the refrigeration system, ice plugging occurs. On the one hand, ice plugs become refrigerants, and semiconductor small thermostats do not normally cool; on the other hand, water also reacts with refrigerants, synthesizes hydrochloric acid and hydrogen fluoride, and turns into corrosion of metal pipes and components. It will cause insulation damage of the electromechanical winding, and at the same time it will become the smell of the refrigerating machine oil, and the compressor will be smooth, so the water in the system is forced to operate at a relatively low limit.
The semiconductor small thermostat should try to avoid the blockage of its refrigeration system. If there is a blockage, it is also necessary to contact the technician to solve it in time.
관련 권장 사항
-
특수 환경을 위한 컴포넌트 및 구성 요소 테스터
1696반도체 산업의 지속적인 발전과 함께 부품 구성 요소 테스트는 산업, 과학 연구, 제약 및 화학 산업 분야의 부품에 널리 사용되었습니다. 현재, 꽤 많은 ...
세부 정보 보기 -
The use and characteristics of the SUNDI series of high and low temperature cooling circulators
1297The SUNDI series of high and low temperature cooling circulators are equipment for direct or auxiliary heating in the fields of biology, physics, chemical engineering, medical treatment, environmental protection, etc. Moreover, the temperature con...
세부 정보 보기 -
Precautions For Compressor Installation of the Screw Chiller Factory
1156When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate ...
세부 정보 보기 -
LNEYA 정밀 테스트 서모스탯 시스템 설계 지침
1086랩핑 테스트 서모스탯은 칩 산업에서 다양한 반도체의 온도를 제어하는 데 사용되는 장치로, 성능을 테스트하기 위해 온도 범위를 제어합니다. 따라서 랩핑 테스트 서모 스탯 시스템은 ...
세부 정보 보기