LNEYA semiconductor refrigeration unit common fault description
If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary to check the space ventilation condition of the semiconductor refrigeration device. If the space is small and the ventilation is not good, it is easy to cause a high-pressure alarm. In addition, if the compressor discharge pressure is too high, pressure relief is required. Turn on the pressure relief valve and put some gas on it.
Leakage refrigerant is one of the more common faults in semiconductor refrigeration equipment. There are many causes of refrigerant leakage in refrigeration systems of semiconductor refrigeration equipment, mainly in the welding area, which has its own manufacturing problems and is caused by customers. Leaking the refrigerant directly causes the semiconductor refrigeration unit to be unable to cool, and it is necessary to check for leaks. Check that it is leaking refrigerant in that place, and then make it up.

The low-temperature alarm and leakage refrigerant of the semiconductor refrigeration device are closely related. The first thing to do is to check whether the refrigerant is leaking. Most of the low-voltage conditions are caused by the leakage of the refrigerant in the semiconductor refrigeration device. Therefore, it is necessary to check the refrigerant and still need to check for leaks. If the compressor of the semiconductor refrigeration unit does not work, it is necessary to check whether the water pump of the semiconductor refrigeration device is good or bad. If the water pump is good, it is necessary to see if the water in the semiconductor refrigeration device tank can be replenished, and then check the current.
Since the semiconductor industry has certain requirements for the operation efficiency of the semiconductor refrigeration device, it is better for the semiconductor refrigeration device to avoid these faults as much as possible.
관련 권장 사항
-
심순환 냉각기의 고압 고장에 대한 솔루션
1025심순환 냉각기는 화학 및 제약 중간체, 석유화학, 기계, 의약품, 전자, 전자, 신소재, 항공우주, 광전자 기술 및 새로운 전자 제품의 생산 및 가공에 사용되는 공정 냉원입니다.
세부 정보 보기 -
How does the cooling and heating system achieve simultaneous temperature control?
1062Temperature control system The thermostat has heating and cooling functions, and can use the same medium for continuous temperature control from -120℃~320℃. The heating and cooling system of cooling and heating system is mainly composed of four pa...
세부 정보 보기 -
What kind of battery pack test chamber meets the laboratory?
802The application of battery pack test chamber in the laboratory needs to meet a series of strict requirements to ensure the accuracy and safety of the test results. These requirements mainly involve the following aspects: Temperature cont...
세부 정보 보기 -
Practical application of different compressors in the industrial chiller industry
968In the current refrigeration industry, the efficiency of the equipment is closely related to temperature. LNEYA tells you that the efficiency of the refrigeration equipment required under control has been improved. Then, the selection of the compr...