리액터용 장비는 어떻게 선택하나요?
The choice of equipment for the reactor needs to be measured by the following points:
1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between.
2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 degrees, equipped with a cooling machine; there is also an oil cooling, suitable for high temperature resin, but the temperature should be greater than or equal to 200 degrees.
3. Material: Generally, there are SUS304 stainless steel, Q235 carbon steel, SUS316 stainless steel, etc.;
4. Stirring method: inclined blade type with inclined angle of 45-60 degrees; anchor type with scraping edge scraping; dispersing disc type with 1000/1500/2800 rpm for shearing (for paint or powder, Hot melt adhesive (rubber); and ribbon type for high viscosity with dispersing disc (for hot melt adhesive)
5. Sealing form: generally has mechanical seal, packing seal, double sealing surface, single sealing surface;
6. Structural aspects: generally have outer half tube type (more than or equal to 2 tons); outer jacket type (more than 3 tons); inner coil; no jacket (no heating); inner coil type (suitable for small viscosity, Small fluidity)).
7. The structure of the kettle body: determined according to size, material and thickness;

Wuxi Guanya LNEYA refrigeration heating temperature control system is the first choice for the reactor equipment, ultra-high temperature cooling technology, can directly cool down from 300 degrees high temperature. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
관련 권장 사항
-
약 60p 냉장 냉각기 에너지 소비가 너무 큼
139860p 냉장 냉각기의 성능은 제조업체마다 다르며 에너지 소비량도 다릅니다. 60p 냉장 냉각기의 에너지 소비가 너무 많으면 제때에 확인하여 확인해야합니다.
세부 정보 보기 -
Purchasing Strategy of Ultra-low Temperature Freezer
984The performance of refrigeration system determines the overall performance. If refrigeration technology is good, excellent refrigeration effect can be achieved quickly. It takes only 4-5 hours on average from room temperature to minus 8 degrees Ce...
세부 정보 보기 -
재료 노화 테스트를 위한 저온 및 고온 시뮬레이션 장비를 선택하는 방법은 무엇입니까?
1140재료 노화 테스트는 많은 산업에서 사용되지만 온도가 테스트 과정에서 필수 불가결하고 중요한 역할을 하기 때문에 고품질 저온 및 고온 시뮬레이션 장비를 선택하는 방법은 매우 중요합니다. LNE...
세부 정보 보기 -
냉각수 욕조 선택 방법 및 관리 포인트
1082소위 냉장 온도 조절기는 이름에서 알 수 있듯이 일정한 온도를 제공하는 장치입니다. 일반적으로 인큐베이터, 온도 조절기 등으로도 불립니다. 냉각 욕조를 더 잘 사용하기 위해 충분히 알아야 합니다.
세부 정보 보기