저온 산업에서 열악한 냉동 성능과 냉매의 관계
The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are relatively low, and the expansion valve and the evaporator are in operation. The balance pressure cannot be maintained. Therefore, if the refrigerant leaks from the low-temperature industrial refrigerator (group) is found, it is not rushed to fill the system with the refrigerant. Instead, the leak point should be immediately found and the refrigerant should be filled after repair.
In the refrigeration system of the low-temperature industrial refrigerator (group), pay attention to the amount of refrigerant, too little, too much, too much, too much may cause the exhaust pressure of the low-temperature industrial refrigerator to rise, higher than the normal value, need to stop in time, use High pressure exhaust removes excess refrigerant from the system.
If the low-temperature industrial refrigerator (group) is filled with too much refrigerant after maintenance, the cooling effect will be worse, because the charge of the refrigerant will occupy a part of the condenser of the low-temperature industrial refrigerator (group), which is reduced. The cooling area and cooling efficiency are also decreasing, and the cooling rate is continuously decreasing. Therefore, according to the operation sequence, after the machine is shut down for a few minutes, excess refrigerant is released at the high pressure shut-off valve, and the residual air in the system can be released at the same time.
Of course, the refrigeration system inside the low-temperature industrial refrigerator (group) also needs to pay attention to, once the air in the low-temperature industrial freezer (group) refrigeration system will reduce the cooling efficiency, this time can be several times after a few minutes after the shutdown The high pressure shut-off valve releases air, and it is also possible to properly fill some refrigerant according to the actual situation.
The refrigeration effect of the low-temperature industrial refrigerator (group) is closely related to the amount of refrigerant. Therefore, users should pay attention to the refrigeration effect in time and strive for better operation of the low-temperature industrial refrigerator (group).
관련 권장 사항
-
Introduction of temperature control equipment for cannabis extraction
1088CO2 is a unique solvent because its dissolving power can be changed by simply adjusting the temperature and pressure during the extraction process. When the pressure and temperature of CO2 are higher than 1083 psi and at 88F, CO2 is considered sup...
세부 정보 보기 -
좋은 소식입니다! 우시 관야 LNEYA 냉동이 새로운 이름을 얻었습니다.
2684장쑤성 쑤난 국가 독립 혁신 시범구에서 발표한 '2019년 장쑤성 남부 국가 독립 혁신 시범구 유니콘 및 가젤 기업 평가 결과 발표에 관한 통지'에 따르면, 장쑤성 쑤난 국가 독립 혁신 시범구에서 유니콘 및 가젤 기업에 대한 평가 결과가 발표되었습니다.
세부 정보 보기 -
The Application of Industrial Chillers
981The chiller machine is needed in a lot of industries, basically chemical, medical, pharmaceutical industries are involved, then what industry can Wuxi Lneya chiller meet in the end? It is known that we are one of the top chiller manufacturers. Th...
세부 정보 보기 -
반도체 레이저 자동 온도 제어 장비 액세서리 결함 솔루션
1209반도체 레이저 자동 온도 제어 압축기 프로스팅, 순환 물 순환 또는 밸브가 열리지 않을 수 있으며, 물 밸브, 모든 파이프 라인을 확인하여 원활하게 단락 파이프 라인을 설치하십시오. 서큘라틴이 ...
세부 정보 보기