주사 전자 현미경 냉각수 순환 시스템
Scanning Electron Microscope (SEM) is a high-resolution microscope widely used in materials science, biology, nanotechnology and other fields. SEM generates a certain amount of heat during operation. In order to ensure the stable operation and image quality of the microscope, an efficient cooling water circulation system is required to control the temperature inside the SEM.
The following are the key components and working principles of the cooling water circulation system of the scanning electron microscope: Key components:
- Circulation pump: responsible for promoting the circulation of cooling water in the system to ensure that the cooling water can flow evenly through various cooling points inside the SEM.
- Cooling water tank: stores cooling water, usually contains filters and chemical additives to maintain the purity of cooling water and prevent corrosion.
- Heat exchanger: transfers the heat in the cooling water to the external cooling medium (usually air or water) through the heat exchanger to achieve the purpose of cooling.
- Temperature controller: monitors the temperature of the cooling water and adjusts the temperature of the cooling water through automatic control systems such as PID controllers to ensure that it is stable within the set temperature range.
- Filter: Filter impurities in cooling water to prevent clogging of the cooling system.
- Pipes and valves: Connect various components to ensure that cooling water can circulate smoothly.
Working principle:
- Cooling water circulation: Cooling water flows out of the cooling water tank and enters the cooling channel or cooling plate inside the SEM through the circulation pump to absorb the heat generated inside the SEM.
- Heat exchange: The cooling water that has absorbed heat then flows into the heat exchanger, where the heat is transferred to the external cooling medium through the heat exchanger to achieve cooling of the cooling water.
- Temperature control: The temperature controller continuously monitors the temperature of the cooling water and adjusts the speed of the circulation pump, the flow rate of the cooling water or the working state of the heat exchanger as needed to keep the temperature of the cooling water stable within the set range.
- Circulation reflux: The cooled cooling water returns to the cooling water tank again to prepare for the next cycle.
- Filtration and maintenance: After a period of use, the cooling water needs to be filtered to remove impurities, and the cooling water and chemical additives need to be replaced regularly to keep the system clean and efficient.
Key requirements:
- Temperature control accuracy: It is usually necessary to control the temperature of the cooling water within the range of ±0.5°C to ±1°C to ensure the stability of the temperature inside the SEM.
- Circulation efficiency: Ensure that the cooling water can circulate efficiently to avoid local overheating. • Safety and protection: The system should have safety measures such as over-temperature protection and pressure protection to ensure the safe operation of the equipment.
- Low noise: The circulation pump and heat exchanger should reduce noise as much as possible to avoid interference with the operation of the SEM.
- Maintenance convenience: The design should be easy to maintain and clean to ensure long-term stable operation.
In summary, the cooling water circulation system of the scanning electron microscope ensures the stability of the temperature inside the SEM by accurately controlling the temperature of the cooling water, thereby improving the imaging quality and stability of the microscope.
관련 권장 사항
-
새로운 에너지 기업을 위한 냉각수 냉각기에는 어떤 테스트가 사용되나요?
961제품 개발, 생산 및 품질 관리 과정에서 새로운 에너지 기업은 냉각수 냉각기를 사용하여 다양한 테스트를 수행합니다. 냉각수 냉각기는 이러한 테스트에서 성능을 보장하기 위해 중요한 역할을 합니다.
세부 정보 보기 -
What instruments in biopharmaceutical processes require cooling water systems?
886In biopharmaceutical processes, many critical equipment and instruments require cooling water systems to maintain their normal operation and process temperature control. The following are some common types of equipment that require cooling w...
세부 정보 보기 -
Refrigeration Unit Water Cooling Chiller
821The chiller water cooling system is an efficient cooling solution that removes heat by circulating cooling water. This system is widely used in industrial, laboratory and commercial environments, especially in applications that require precis...
세부 정보 보기 -
알아야 할 수냉식 냉각기의 장점
1129산업용 냉각기는 일반적으로 냉동 유형에 따라 수냉식 및 공냉식으로 나눌 수 있습니다. 수냉식 냉각기의 열교환 매체는 물입니다.LNEYA는 새로운 유형의 온도 제어를 설계하고 개발했습니다 ...
세부 정보 보기 -
40GW 극저온 냉각기의 유형 선택 및 분류에 대한 설명
1187If different enterprises and different industries have different requirements for Wuxi Guanya 40GW cryogenic chillers, its model selection is also different. So it is better to have a clear understanding of the needs of the selection of 40GW cryog...
세부 정보 보기 -
New energy vehicle high and low temperature test system
932With the popularity of new energy vehicles, high and low temperature tests have become a factor that car owners need to consider when purchasing new energy vehicles. Since the environment in which new energy vehicles are used is harsher, it is als...
세부 정보 보기 -
초저온 컴프레서 장치에서 필터의 작용에 대한 설명
1142In order to stabilize the operation of the ultra-low temperature compressor unit, the performance of the compressor is very important, and in addition to the compressor, the filter is also important. In order to maintain normal operation, it is ne...
세부 정보 보기