전체 방송국 검색

Chillers and Heaters

SUNDI -60℃~+250℃

냉각 용량 0.25kW~60kW
난방 전력 2.5kW~60kW
중간 온도 정확도 ±0.5℃
에너지 소비량

The temperature control range of this process chiller heater is -60℃~250℃, the temperature control accuracy of the heat transfer medium is ±0.5℃, and the temperature control accuracy of the reaction material is ±1℃, which meets your pursuit of temperature control stability and accuracy.

SUNDI 시리즈

-60°C

최저

250°C

최고

±0.5°C
±1℃

온도 제어 정확도

매체 및 소재


SUNDI- 625
625W
635
635W
655
655W
675
675W
6A10
6A10W
6A15W 6A25W 6A38W 6A60W
온도 범위  -60℃~+250℃
중간 온도 정확도 ±0.5℃
재료 온도 정확도 ±1℃
난방 전력 2.5 3.5 5.5 7.5 10 15 25 38 60
냉각 용량 250℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60
-40℃ 0.95 1.45 2.3 3.1 4.8 7.8 18 23 31
-55℃ 0.25 0.5 0.75 0.9 1.5 2.8 6 8 11
Flow、pressuremax  L/min bar 20 35 35 50 60 110 150 200 250
1.2 1.2 1.2 1.2 1.5 1.5 1.5 1.5 2.5
냉각수
@20℃
1100L/H
1.5bar~4bar
ZG1/2
2000L/H
1.5bar~4bar
ZG3/4
2300L/H
1.5bar~4bar
ZG3/4
2600L/H
1.5bar~4bar
ZG3/4
3300L/H
1.5bar~4bar
ZG1
4000L/H
1.5bar~4bar
ZG1 1/4
8.5m³/H
1.5bar~4bar
DN40
14m³/H
1.5bar~4bar
DN50
20m³/H
1.5bar~4bar
DN65
치수 cm 55*70*175 55*70*175 55*70*175 65*85*185 65*85*185 80*120*185 150*100*185 200*145*205 200*145*205
전원 380V 50HZ 5kW 10kW 12kW 18kW 22kW 28kW 56kW 73kW 110kW
휴대용 공기 및 물 냉각기

3점 온도 제어

20개 프로그램 컴파일 가능

높은 정밀도와 높은 효율성을 보장하는 열쇠

장점Chillers and Heaters

Technological innovation
LNEYA invests at least 7% of its turnover in innovation and research and development each year, and currently has 90 patents. It is at the international leading level in the research and development of single-machine cascade refrigeration technology and single-medium temperature control of reactors.
 
자기 구동 펌프
SUNDI-60℃~250℃ chiller heaters are equipped with magnetic drive pumps. Since no mechanical seal is used, there is no shaft seal leakage problem, and you do not need to spend money to regularly check the pump for leakage or replace the mechanical seal.

높은 정밀도와 높은 효율성을 보장하는 열쇠

WATER Chillers and Heaters 애플리케이션


추출
Extraction is a process of separating the target substance from a mixture through a solvent. The principle is that different components have different solubility in the solvent. The temperature needs to be strictly controlled during the extraction process to prevent the target component from decomposing at too high a temperature or incomplete reaction at too low a temperature. This requires the use of a chiller heater combo.

Distillation and rectification
In molecular distillation or azeotropic distillation, the refrigeration system and heating system of the process chiller heater respectively control the temperature of the condensation section and the heating section to help evaporate high-boiling substances and cool down to recover the target components.
 
Crystallization and recrystallization
SUNDI-60℃~250℃ chiller heater unit plays an important role in the crystallization process of chemicals. Accurate temperature control can regulate the growth rate of crystals and avoid impurities in the crystals. During the recrystallization process, rapid cooling can inhibit side reactions and improve crystal uniformity.

동적 온도 제어 시스템용 기타 모델

신뢰할 수 있는 이동식 냉각기 공장

당사는 자체 공장과 온도 제어 분야에서 20년 이상의 경험을 보유한 매우 강력한 냉각기 공급업체입니다.

LNEYA has a professional design and R&D team, 90+ invention patents, and more than 15 years of production experience. Basic research such as simulation and thermal energy is provided by a doctoral team to provide guarantee for application technology, realizing the integration from selection, calculation, 3D, and drawings. It can be customized according to your requirements.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

Our main products include refrigeration and heating circulators, dynamic temperature control systems, freezers, semiconductor chillers, new energy test chillers and other equipment.

We use 100% helium testing and safety testing, and the chillers are continuously copied for 24 hours before leaving the factory to ensure that the chillers and water heaters you receive have no quality problems.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!