Lneya’s high and low temperature cooling circulator instructions
The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according to their instructions.
The high and low temperature cooling circulator is a device that uses mechanical refrigeration to obtain low temperature heating tube heating to obtain high temperature, a leak-free shielding pump as a circulation pump, a double-layer glass reaction bath, a stainless steel sandwich reaction kettle and the like. Before using the high and low temperature cooling circulator, open the wooden box and first install the inlet and outlet valves on the liquid inlet. (Note: The upper and lower sides of the machine are marked with inlet and outlet ports, the valve is a shut-off valve, the valve medium flows in a direction, and the valve is marked with a flow direction. The valve and the reaction kettle are docked with a hose, and the inlet and outlet of the reaction kettle should be driven in, out, and react. Keep the liquid in the kettle. Open the high and low temperature tank and add the liquid to the machine to open the machine’s circulation switch, let the liquid circulate throughout the system. (Note: To evacuate the air in the system) The cooling medium should meet the conditions of use. That is, it does not freeze under low temperature conditions, and does not boil under high temperature conditions)
If the high and low temperature cooling circulator requires a temperature of 150 ° C, set the temperature control table to 150 ° C to turn on the heating switch and the cycle switch, and the machine will start working. When the material needs to be cooled to room temperature at high temperature, it is necessary to turn off the heating and turn on the pre-cooling. At this time, the material can be cooled to room temperature by cooling. When the material needs to be lower than room temperature, first reduce the material to room temperature, then set it to the required equipment, turn on the refrigeration, the compressor will enter the working state, and the machine will start to cool down.
During the use and maintenance process, try to operate according to the requirements. It is not recommended to change the program by yourself to avoid the failure of the high and low temperature cooling circulator. (This article is from the source network, if there is any infringement, please contact Lneya to delete, thank you.)
관련 권장 사항
-
Introduction of Industrial Chillers by Industry Manufacturers
1428Industrial chiller is a kind of industrial cooling equipment, which is mainly used to solve the reaction temperature control problems such as machine overheating caused by industrial production. The common reaction kettle in industrial production ...
세부 정보 보기 -
순환 유체 온도 제어 장치의 보호 장치 세부 정보
1198순환 펌프 과부하 보호 기능은 순환 액체 온도 조절 장치가 너무 클 때 순환 펌프의 주 전원을 차단하는 기능입니다. 재설정 시 녹색 버튼을 누르고 빨간색 버튼은 정지 버튼입니다...
세부 정보 보기 -
Chip temperature control device detection application technology
1159The chip temperature control device is mainly used in the field of chip testing. For different types of chip types, the detection technology also needs attention, so it is necessary to pay attention to the practical application of different detect...
세부 정보 보기 -
구체적인 작동 분석 산업용 냉동고 사용 시 제습 방법
1254산업용 냉동고를 사용하는 과정에서 냉동 시스템에 약간의 습기가있을 수 있습니다. 따라서 산업용 냉동고의 제습은 매우 중요하므로 제습하는 방법은 무엇입니까? 제습시 산업용을 구매하는 사용자는 ...
세부 정보 보기