소형 환경 테스트 챔버 압축기는 유지 보수 후주의를 기울여야합니다.
원심식 소규모 환경 테스트 챔버에서 흡입 회수 장치는 일반적으로 독립 시스템이며, 필요한 경우 응축기와 증발기에 연결된 파이프 라인을 닫아 별도의 유지 보수를 할 수 있습니다. 후 ...
After replacing the compressor in the small environmental test chamber, the pumping recovery device generally uses the automatic mode to open, stop and work during the operation of the unit. Therefore, the oil level of the oil separator of the piston compressor should be strictly monitored. Strictly monitor the level of the refrigerant in the recovery condenser. If the liquid level is not visible, the recovery condenser is not effective. Check whether the coolant line and the filter are blocked. If the non-condensable gas removed by the bleed valve contains more refrigerant gas, check if the float valve at the top of the recovery condenser is stuck.
If the venting valve that is automatically vented in the small environmental test chamber does not open the deflation when the specified pressure value is reached, the operation of the suction recovery device should be stopped and the exhaust valve should be overhauled. Frequent activation of the pumping recovery unit indicates that a large amount of air has leaked into the unit. Before the start of the refrigeration unit or during the start-up process, the manual operation of the suction recovery device is generally adopted. The time of each operation is limited by the decrease of the condensing pressure and the heat of the piston compressor motor casing. Generally, the continuous operation time is less than 30 minutes. If the small environmental test chamber is not used for a long time, it can be turned on for a short time to lubricate the compressor part. If the small environmental test chamber does not need to exclude non-condensable gases, the unit should also be operated for 15 to 20 minutes per day or several days.

The maintenance of the small environmental test box is also inevitable. It is recommended to make regular maintenance plans and carry out maintenance in a timely and effective manner.
관련 권장 사항
-
Temperature conditions of new energy vehicle batteries
926When automobile manufacturers continue to improve battery life to overcome the driver's mileage anxiety, the energy density of the large batteries installed is also gradually increasing, which means that the temperature monitoring function of the...
세부 정보 보기 -
API exhibition LNEYA is brilliant
1279On October 14, 2020, the 85th China International Pharmaceutical Raw Materials/Intermediates/Packaging/Equipment Fair (API China for short) was grandly opened at Nanjing International Expo Center. The exhibition site was bustling and popular. LNEY...
세부 정보 보기 -
We are LNEYA, a manufacturer of chillers
1305LNEYA chiller manufacturer is committed tothe R&D, production and sales of refrigeration and heating temperaturecontrol systems, ultra-low temperature freezers, new energy automobilecomponent testing systems, and heating cycle systems. The ...
세부 정보 보기 -
원자로의 열유 온도 제어 시스템에 대한 먼지의 유해성
934Dust in daily work will also have a certain impact on the circuit board work of the thermal oil temperature control system of the reactor. Dust is an unevenly dispersed system composed of particles suspended in the air. It mainly comes from indu...
세부 정보 보기