Precautions for Leakage Inspection of Glycol Chiller
The main points about checking leakage of glycol chiller
During the operation of the glycol chiller, it is critical that the refrigeration system does not leak.
In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy water or other methods. When the refrigeration cycle is in operation, the welds should not be cracked due to vibration, the pipes should not be blocked by debris during welding, and should not enter moisture due to improper operation. When the refrigeration cycle is working, the surface of the welded parts should be clean and clean. No oil stains.
The common leakage points of glycol chillers are evaporator leakage, refrigeration cycle connection leakage, refrigeration cycle valve leakage, compressor pipeline leakage, capillary vibration wear, four-way reversing valve leakage, etc. Common inspections Leakage methods are commonly used in the production and maintenance of refrigeration cycles: visual leak detection, pressure leak detection, instrument leak detection, vacuum leak detection, etc. The user can solve the leakage points one by one.
The fault of leak detection of glycol chiller is relatively common. Therefore, when choosing, it is recommended to choose a fully closed loop piping system and valve parts to choose branded accessories. The evaporator uses a high-power plate heat exchanger, which is small in size, high in efficiency, fast in cooling, safe and reliable, and is used for rapid liquid cooling. It is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.
Related recommendations
-
2018 CIPM China | You have an invitation to the exhibition from LNEYA
2446The 56th (Fall 2018) National Pharmaceutical Machinery and China International Pharmaceutical Machinery Expo will be held from November 5th to November 7th, 2018 at Wuhan International Expo Center. As one of the professional communication platfor...
View details -
Classification and Application of Industrial Water Chillers
2360In lots ofindustrial production processes, it is difficult to obtain high efficientindustrial production efficiency if there is no industrial water chiller toprovide a low temperature production environment. Therefore, industrial water chill...
View details -
How to judge the operating status of the chemical and pharmaceutical constant temperature control sy
2016Nowadays, many pharmaceutical and chemical industries use LNEYA's constant temperature control system. How to judge its operation status during operation? There should be no noise in the cylinder of the chemical and pharmaceutical thermostatic con...
View details -
Parameters of small gas condensing liquefaction system
2184During the process of loading and unloading gasoline and refueling vehicles, and collecting high-concentration gas from the chemical plant. One or two methods in the process of adsorption or condensation, or the conversion of oil and gas from a ga...
View details
LNEYA Thermo Refrigeration Co.,Ltd