글리콜 냉각기 누출 검사 시 주의사항
The main points about checking leakage of glycol chiller
During the operation of the glycol chiller, it is critical that the refrigeration system does not leak.

In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy water or other methods. When the refrigeration cycle is in operation, the welds should not be cracked due to vibration, the pipes should not be blocked by debris during welding, and should not enter moisture due to improper operation. When the refrigeration cycle is working, the surface of the welded parts should be clean and clean. No oil stains.
The common leakage points of glycol chillers are evaporator leakage, refrigeration cycle connection leakage, refrigeration cycle valve leakage, compressor pipeline leakage, capillary vibration wear, four-way reversing valve leakage, etc. Common inspections Leakage methods are commonly used in the production and maintenance of refrigeration cycles: visual leak detection, pressure leak detection, instrument leak detection, vacuum leak detection, etc. The user can solve the leakage points one by one.
The fault of leak detection of glycol chiller is relatively common. Therefore, when choosing, it is recommended to choose a fully closed loop piping system and valve parts to choose branded accessories. The evaporator uses a high-power plate heat exchanger, which is small in size, high in efficiency, fast in cooling, safe and reliable, and is used for rapid liquid cooling. It is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.
관련 권장 사항
-
Description of the development of the wafer chip test system
999With the development of the semiconductor industry, the wafer chip test machine has also made great progress. How much do you know about the development of the wafer chip test machine? The integrated circuit industry has gradually emerged since th...
세부 정보 보기 -
난방 쿨링 서큘레이터의 가격은 어떻게 결정되나요?
976The price of heating cooling circulator is determined by raw materials, manufacturing overhead, technical cost, impacting on the final quotation. The heating cooling circulator is made of shell and internal parts. The shell is applied standard SUS...
세부 정보 보기 -
고온 저온 테스트 챔버의 가격 분석
1086속담에 "지불한 만큼 얻는다"는 말이 있습니다. " 고온 저온 테스트 챔버의 가격은 구성의 품질과 관련이 있습니다. 우시 LNEYA의 기술 자체는 귀중합니다. 테스트 챔버 산업에서 고온 저온은 ...
세부 정보 보기 -
심순환 냉각기의 고압 고장에 대한 솔루션
1022심순환 냉각기는 화학 및 제약 중간체, 석유화학, 기계, 의약품, 전자, 전자, 신소재, 항공우주, 광전자 기술 및 새로운 전자 제품의 생산 및 가공에 사용되는 공정 냉원입니다.
세부 정보 보기