How to eliminate the failure of large thermal shock test chamber?
As technology continues to advance and improve, LNEYA recommends strict requirements for operators of large thermal shock test chambers. If used improperly, operators need to be able to face and resolve these problems in a timely manner.
A large thermal shock test chamber can be formed by the tank, the air circulation system, the refrigeration system and the heating system. When the high and low temperature experiments are carried out, the temperature rise is very slow, and the wind circulation system may not be normally opened, and the temperature change If the experimental temperature is not reached, it is necessary to solve the problem according to different states.
If the large-scale thermal shock test chamber does not reach the temperature change of the test index at low temperature, it may be that the temperature will always be very slow, or it may rise after the temperature reaches a certain value. When the above 2 cases occur, It is necessary to check whether the test chamber is in a dry environment before the low temperature test. After the test chamber is kept in a dry environment, the test sample can be placed indoors for testing. Another reason is whether the sample is placed too much, so that the air circulation in the room circulates. If this is not the case, the operator should contact the manufacturer for professional repairs.
There is another factor that may cause the failure, that is, the temperature control of the large thermal shock test chamber is not good, and the temperature in the laboratory where the equipment is placed is an environment with an average temperature of 25 ° C in 24 hours, and the humidity is about ≤ 85%. RH is fine. Even the best equipment needs a good place to be placed, and the large thermal shock test chamber is no exception. In order to ensure that the equipment can reach the temperature during the test and the life is extended, every operator should maintain it.
If the large-scale thermal shock test box fails, the operator needs to perform professional fault resolution to make the test box run smoothly.
Related recommendations
-
What are the applications of steam circulators in chemical industry?
2040The steam circulator in the chemical industry is a temperature control equipment in the pharmaceutical and chemical industry. When users operate, they need to understand the performance and maintenance knowledge in order to operate the equipment e...
View details -
Buying Tips of Ultra Low Temperature Freezer
2123As for the industrial refrigerating treatment, the ultra low temperature freezer is indispensable. Let me tell you something about it! The ultra low temperature freezer of Wuxi Guanya Refrigeration technology co., Ltd is mainly used in industrial ...
View details -
Heat transfer oil for cooling and heating temperature control systems in the chemical and pharmaceut
2332The cooling and heating temperature control system, also known as a high and low temperature circulator or dynamic temperature control system, is a temperature control equipment used in the pharmaceutical and chemical industry to provide cold and ...
View details -
What if the cooling rate of the cooling and heating temperature control system of the reactor slows
2294LNEYA cooling and heating temperature control system is a laboratory instrument and equipment for temperature control of supporting reactors in pharmaceutical and chemical laboratories and other industries. It adopts a fully closed circulation pip...
View details
LNEYA Thermo Refrigeration Co.,Ltd