What are the main points for regular maintenance of the recirculating chiller?
Recirculating chillers are used frequently in the industry, and the heat generating parts of various devices require recirculating chillers, so operating efficiency is very important.
During the running time of the recirculating chiller, it is necessary to frequently check whether the cooling water pipe connection is safe and firm. Whether the flow, temperature and pressure of the cooling water are appropriate, so as not to affect the cooling effect of the recirculating chiller if the water flow is too large or too small.

The operator also needs to set a time to check the circulating water position of the water tank on a specific date each year to avoid the water level drop without knowing it, resulting in insufficient circulating water supply, so regular inspections and replenishment of circulating water.
During the use of the recirculating chiller, in order to prevent the growth of microorganisms and other substances in the circulating water and affect the cooling effect of the recirculating chiller, it is necessary to pay attention to water quality issues. It is recommended to check the water quality problems regularly and to replace the water quality at least annually.
In addition, the compressor air-cooled filter and the cooling fan blades in the recirculating chiller should be cleaned regularly. It is recommended that they should be cleaned every 6 months. After the cleaning is completed, 1 to 2 drops of oil should be added to the recirculating chiller fan bearing.
In order to reduce the impact of the scale of the recirculating chiller on the flow and cooling capacity, the pipeline is cleaned every 5 years (every 2 years if the tap water is used for cooling) to reduce the generation of pipeline scale.
관련 권장 사항
-
온도 조절기 시스템을 배치할 때 주의해야 할 사항은 무엇인가요?
970다른 제조업체에서 생산하는 고온 및 저온 서모 스탯 시스템의 크기와 성능에는 특정 차이가 있습니다. 사용자는 구매 후 배치 할 때 배치 방법에주의를 기울여야합니다.
세부 정보 보기 -
How to deal with the equipment failure alarm of the recirculation chiller
958What to do if there is a failure and alarmduring the use of the recirculating chiller equipment? In order to ensureproduction, such problems need to be resolved quickly. We must first understand the causes offailures and alarms, and adopt dif...
세부 정보 보기 -
What is the reason why the industrial chiller system cannot be cooled
1292Let the LNEYA technical engineer explainthe reason for everyone: The first one: The chiller system fails tolower the temperature during the first use, or there is a problem with theinstallation of the industrial water chiller, cooling tower, ...
세부 정보 보기 -
초저온 냉동고 청소
925초저온 냉동고 환경 청소: 한 달에 한 번위생 용품으로 모든 지상 파편과 먼지를 청소하고 압축기 및 냉동 시스템의 먼지 흡착을 줄이고 열 방출에 영향을 미칩니다.