Basic structure manual of industrial chiller
Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories.
1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to increase the pressure of the refrigerant in the system, so that the refrigerant circulates in the refrigeration system to achieve the purpose of refrigeration.
2. Condenser: The high temperature and high pressure Freon of the refrigeration system enters the condenser after coming out of the compressor, releases a lot of heat to the cooling medium, and is then cooled and liquefied.
3. Evaporator: When the freon liquid in the refrigeration system enters the expansion valve for throttling and is sent to the evaporator, it belongs to the vaporization process. At this time, it needs to absorb a lot of heat, gradually reduce the valence and mass temperature, and achieve the effect of cooling.
4. Expansion valve: In the flow chart of the refrigerant system of the industrial chiller, we found that there is a small part between the condenser outlet and the evaporator inlet, which is called thermal expansion valve. It is a throttling and decompression component that reduces the condensing pressure of the refrigerant to the evaporating pressure. Therefore, its role in the refrigeration system is essential. It is connected with the refrigeration compressor, evaporator and condenser, also known as the four major components of the refrigeration system.
5. Other accessories: including drying filter and high and low pressure controller. The filter drier is not removable. The internal structure adopts molecular sieve structure, which can remove a small amount of impurities and moisture in the pipeline, thereby purifying the system. High and low pressure controllers play a protective role in the refrigeration system.
Related recommendations
-
About 60p Refrigerated chiller energy consumption is too large
2708The performance of 60p Refrigerated chiller of different manufacturers is different, and the energy consumption is also different. If the energy consumption of 60p Refrigerated chiller is too large, it is necessary to check in time to see if ther...
View details -
The Method That Small Water Cooled Chiller Needs To Follow When Charging Refrigerant
2187In our life, we believe that everyone is very familiar with refrigeration. In the central air conditioning and industrial production process cooling industry, small water cooled chiller is more common. This unit is composed of a compressor in the ...
View details -
Basic maintenance of high and low temperature refrigeration circulating pumps
2714Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protect...
View details -
Detailed explanation of closed circulation cooling system debugging attention
2256The preparation of the closed circulation cooling system before commissioning is an important part of the debugging process, which may affect the progress of the whole debugging process. Generally, attention should be paid to the leakage detection...
View details
LNEYA Thermo Refrigeration Co.,Ltd