Introduction to the quality and configuration of industrial refrigeration and heating circulators
With the development and progress of society, industrial refrigeration and heating circulators are used more in the industry, and the technological level is becoming more and more complex. So, what should users pay attention to after purchasing this equipment?

1. In order to consume electricity, many companies will cut off the power after the experiment. According to the technical staff, we explained that if the industrial refrigeration and heating circulator is powered off in winter, the inner tank is prone to aging, thereby reducing the equipment’s performance. service life.
2. During normal use, when the temperature in the box drops to a certain set value, the thermostat will cut off the power by itself. At this time, the pressure of the refrigerant is already very low, and the compressor is relatively small compared to the load of the motor. , the motor is easy to start normally, if the power is forced to be cut off, the power will be turned on immediately when the refrigeration has a relatively high pressure. Although the high voltage will cause the motor to be overloaded, it is easy to burn the motor due to excessive current. Therefore, industrial refrigeration and heating circulators cannot be powered off at will.
3. The industrial refrigeration and heating circulator that is in a power-off state cannot be powered on at will, especially for newly purchased equipment, it must be placed for one to two hours before it can be powered on.
4. There is a certain space between the inner tank and the outer shell. The electric heating tube is used to provide heat to transfer the heat to the heat-conducting oil medium, and then the heat is transferred to the inner tank of the reactor through the heat-conducting oil bath, and the material medium in contact with the inner tank passes through the steel plate. The heat is used to increase the temperature, and the temperature required for the reaction of the material is slowly reached.
5. The electric heating tube is generally 220v/380v voltage, and the 220v electric heating tube must be three in a group, connected to form three power supply requirements (general industrial production does not use direct single-phase wiring), through three in a group, you can According to the total number of electric heating pipes required, multiple groups are formed.
There are certain differences in the quality and configuration of industrial refrigeration and heating circulators from different manufacturers. Users can judge and use them according to the reaction kettle heating and temperature control machine they purchased.
관련 권장 사항
-
Thermostatic bath SC of Lneya refrigeration company
1494Thermostatic bath of Lneya refrigeration company is widely used for drying, distillation, concentration, dipping in chemical reagents, pharmaceutical and biological products, and can also be used for thermostatic bath heating and other temperature...
세부 정보 보기 -
LNEYA ultra-low temperature bath safe operation instructions
944Ultra-low temperature thermostats use more equipment in the pharmaceutical and chemical industries. At the beginning of the new year, each operator needs to pay attention to safety operations, and safely and efficiently operate ultra-low temperatu...
세부 정보 보기 -
Product features of explosion-proof high and low temperature machine
1341LNEYA explosion-proof high and low temperature machine is a relatively temperature control equipment that can be used in the current heating and cooling system. It can be used for simultaneous cooling and heating. It can be combined with various r...
세부 정보 보기 -
High and low temperature equipment manufacturers analyze expansion valve knowledge
1153The expansion valve is an important accessory in the high and low temperature integrated machine. The manufacturer tells you that there are various kinds of expansion valves, and different expansion valves have different differences. The high and ...
세부 정보 보기