Control method for semiconductor test chiller to meet temperature requirements
The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronics manufacturing field needs to provide a constant temperature environment for various electronic components to make them stable Work and achieve better performance, such as: quartz crystal oscillator, electronic linear accelerator, etc.
Although there are many domestic manufacturers of temperature control equipment, there are very few semiconductor test chiller independently developed, especially in high-precision measurement and control. Semiconductor test chiller manufacturers have developed a method that takes into account high accuracy, high stability, and wide adjustment. The range of high-power temperature control systems is significant.
There are currently two types of direct cooling and indirect cooling.
The direct cooling method is a method in which the cooling unit directly cools the circulating water. First, the temperature sensor collects the temperature value to the temperature controller, and then after a specific control algorithm, the temperature controller controls the refrigeration unit and the heating unit to perform cooling and heating processes, respectively, so as to control the temperature near the set value. When the temperature of the circulating water deviates from the set value, the control system first performs cooling or heating processing. After the temperature of the circulating water enters the set threshold range, the temperature of the circulating water is gradually stabilized by fine-tuning the cooling and heating power.
The temperature control method directly controls circulating water, has high temperature control accuracy, and can be used under low temperature conditions; the disadvantage is that the system structure and control program are complicated.
The indirect cooling method is generally a temperature adjustment method by adjusting the flow ratios of the circulating water at two different temperatures and mixing to obtain the required water temperature. The mixing process is mainly achieved by adjusting the opening of the electric three-way valve. First, the temperature sensor detects the temperature of the two circulating waters respectively, and transmits the temperature value to the temperature controller, and then the temperature controller controls the opening of the electric three-way valve according to a specific control algorithm, that is, the two different temperature waters are controlled. The mixing ratio is more than the circulating temperature of the required temperature.
Semiconductor test chiller heat exchanger is a widely used indirect cooling device in modern industrial production, which can realize heat transfer between two or more fluids with different temperatures, so that the temperature of high temperature fluid or low temperature fluid can meet the process requirements. During the work of the heat exchanger, different heat exchange power and heat exchange efficiency are achieved by adjusting the flow rate of the medium or refrigerant. This kind of equipment has a large heat exchange power, usually hundreds of kilowatts or more, and is bulky and difficult to integrate and transport.
LNEYA’s LL series is a chiller specially developed for the field of electronics production testing. This equipment is mainly used for cooling the heating part of semiconductor manufacturing equipment, cooling the heating part of laser devices, and analyzing the heating part of detection devices. The latest upgrade is not only for cooling but also for heating. The temperature control range can reach -5 ° C to 85 ° C, which improves the performance of precision cooling water circulation equipment and expands the application range of the equipment.
Related recommendations
-
Working principle of refrigeration and heating thermostat for chemical industry
2108In the selection process of the special refrigeration and heating thermostat for chemical industry, the heating power and the pressure and flow rate of the heat transfer medium are also factors to be considered. Different raw materials have differ...
View details -
Aspects to be aware of when using an air-cooled all-in-one
1831The air-cooled all-in-one is in operation, unless it is necessary, please do not open the chassis door, otherwise the following adverse consequences may result. When the equipment is subjected to a high temperature test, it is very dangerous to bl...
View details -
Low-temperature cycle equipment operation importance description
2190The use of low-temperature cycle equipment is inseparable from its standard operation. LNEYA low-temperature cycle equipment will be shipped with the corresponding instruction manual, and users can know ahead of time when using it. The low tempera...
View details -
Product features of explosion-proof high and low temperature machine
2566LNEYA explosion-proof high and low temperature machine is a relatively temperature control equipment that can be used in the current heating and cooling system. It can be used for simultaneous cooling and heating. It can be combined with various r...
View details