온도 요구 사항을 충족하기 위한 반도체 테스트 냉각기 제어 방법
The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronics manufacturing field needs to provide a constant temperature environment for various electronic components to make them stable Work and achieve better performance, such as: quartz crystal oscillator, electronic linear accelerator, etc.
Although there are many domestic manufacturers of temperature control equipment, there are very few semiconductor test chiller independently developed, especially in high-precision measurement and control. Semiconductor test chiller manufacturers have developed a method that takes into account high accuracy, high stability, and wide adjustment. The range of high-power temperature control systems is significant.
There are currently two types of direct cooling and indirect cooling.
The direct cooling method is a method in which the cooling unit directly cools the circulating water. First, the temperature sensor collects the temperature value to the temperature controller, and then after a specific control algorithm, the temperature controller controls the refrigeration unit and the heating unit to perform cooling and heating processes, respectively, so as to control the temperature near the set value. When the temperature of the circulating water deviates from the set value, the control system first performs cooling or heating processing. After the temperature of the circulating water enters the set threshold range, the temperature of the circulating water is gradually stabilized by fine-tuning the cooling and heating power.
The temperature control method directly controls circulating water, has high temperature control accuracy, and can be used under low temperature conditions; the disadvantage is that the system structure and control program are complicated.
The indirect cooling method is generally a temperature adjustment method by adjusting the flow ratios of the circulating water at two different temperatures and mixing to obtain the required water temperature. The mixing process is mainly achieved by adjusting the opening of the electric three-way valve. First, the temperature sensor detects the temperature of the two circulating waters respectively, and transmits the temperature value to the temperature controller, and then the temperature controller controls the opening of the electric three-way valve according to a specific control algorithm, that is, the two different temperature waters are controlled. The mixing ratio is more than the circulating temperature of the required temperature.
Semiconductor test chiller heat exchanger is a widely used indirect cooling device in modern industrial production, which can realize heat transfer between two or more fluids with different temperatures, so that the temperature of high temperature fluid or low temperature fluid can meet the process requirements. During the work of the heat exchanger, different heat exchange power and heat exchange efficiency are achieved by adjusting the flow rate of the medium or refrigerant. This kind of equipment has a large heat exchange power, usually hundreds of kilowatts or more, and is bulky and difficult to integrate and transport.

LNEYA’s LL series is a chiller specially developed for the field of electronics production testing. This equipment is mainly used for cooling the heating part of semiconductor manufacturing equipment, cooling the heating part of laser devices, and analyzing the heating part of detection devices. The latest upgrade is not only for cooling but also for heating. The temperature control range can reach -5 ° C to 85 ° C, which improves the performance of precision cooling water circulation equipment and expands the application range of the equipment.
관련 권장 사항
-
Is the centrifugal pump or the volumetric pump selected in the pharmaceutical laboratory?
999In the pharmaceutical laboratory, a variety of refrigeration equipment is used more, then as a more common equipment - pumps, mainly centrifugal pumps, volumetric pumps. Then, the user friend should have a better understanding of their performance...
세부 정보 보기 -
단거리 분자 증류기의 안정적인 운영을 위한 조치
938단거리 분자 증류기가 작동 중에 비효율적이면 관련 냉동 가열 온도 제어 시스템의 사용에 영향을 미칩니다. 단거리 분자 증류기는 어떻게 안정적인 작동을 유지합니까? 증기가...
세부 정보 보기 -
Semiconductor Testing Dual Channel heating Circulator Unit
837The dual channel heating cycler in semiconductor testing refers to a device used to test semiconductor devices (such as power semiconductors), which can simultaneously control two independent testing channels to perform heating and cooling...
세부 정보 보기 -
열수력 원자로에 사용되는 냉동 가열 온도 제어 시스템 장비
916냉동 가열 온도 제어 시스템은 다양한 반응기, 반응기 및 증류 장비에 사용할 수 있습니다. 오늘은 열수 반응기에 적용할 때 주의해야 할 사항을 분석해 보겠습니다. 열전달 매체 ...
세부 정보 보기