Reactor refrigeration systems are widely used in industry, so basically speaking, reactor refrigeration systems are mostly used in industry. In seasons with high ambient temperatures, the usage rate will be higher. By understanding the operation of these four processes, you can understand their working principles.
1. The refrigerant used in the reactor refrigeration system can not only largely cool down at higher temperatures, but also rapidly improve the quality of the processed product. When using it, it is necessary to understand its cooling principle. After understanding the cooling principle, we will find out what problems have occurred in the equipment, and the reactor refrigeration system manufacturer will be able to detect them in a timely manner to facilitate the search for causes.
2. “If the refrigerant wants to function properly, it must have a refrigerant. After the reactor refrigeration system is thermally compressed by a compressor, a condition of high temperature and high pressure is formed.”.
3. The compressed gaseous refrigerant in the condenser is cooled and condensed at an equal pressure, and after condensation, it changes into a liquid refrigerant, which then expands to a low pressure through a throttle valve and becomes a gas-liquid mixture. After absorbing heat, this mixture will start over as a gaseous refrigerant. The gaseous refrigerant enters the compressor from the beginning through a pipeline, starting the next cycle.
4. Regular maintenance is very important. If the machine works for a long time, it is important to pay attention to the need to add lubricating oil to reduce friction. Refrigeration lubricating oil is a necessary medium for compressor operation, and whether the refrigeration lubricating oil is normal determines whether the reactor refrigeration system can operate normally. Therefore, high-quality lubricating oil should be used, and attention should be paid to whether various parameters meet the requirements.
5. To make the reactor refrigeration system more effective and usable, cleaning equipment is not only for cleaning the surface, but also for regularly replacing the water entering the circulation system. Otherwise, the pipes may become clogged, which can easily cause problems with the equipment.
관련 권장 사항
-
"2021 고품질 개발상" 수상
16872022년 5월 8일 오후, 우시시 홍산 거리에서 2020년 연례 요약 및 표창 회의가 열렸습니다. 우시관야 항온냉동기술유한공사(Wuxi Guanya Constant Temperature Refrigeration Technology Co. (LNEYA)가 "2020 우수 공헌상"을 수상했습니다.
세부 정보 보기 -
산업 공정에서 LNEYA 냉각기 사용 시 주의사항
12401. 설치 (기계의 손상 여부 확인, 설치 및 유지 보수를위한 올바른 위치 선택) 2. 설치 장치의 위치는 바닥, 장착 매트 또는 기초 여야하며 레벨은 6.4mm 이내이며 걱정을 견딜 수 있어야합니다.
세부 정보 보기 -
화학 산업에서 산업용 냉각기의 디버깅 단계
930After completing the installation of industrial water chillers in chemical enterprises, certain debugging needs to be carried out in the early stage of operation. Only through careful debugging can we find out whether there are hidden troubles in...
세부 정보 보기 -
Semiconductor diffusion furnace configuration temperature control equipment
1091In the semiconductor industry, a diffusion furnace is a device used to manufacture doping layers on the surface of semiconductor materials. It achieves the doping process through high-temperature heating and controlled diffusion atmosphere...