오일 배스 난방 시스템에서 항온 장비의 중요성

The constant temperature equipment of the oil bath heating system is used for dynamic temperature control of fluid cooling and heating with heat conducting medium, which is applied to high-precision industries such as pharmaceuticals, chemicals and semiconductors, and helps customers complete temperature control of the process. It is equipped with biochemical experimental equipment such as reactors, distillation, evaporators, and Rotary evaporator to control the cooling and heating of heat conducting medium or reaction materials.
The power switch of the transformer cooling system control box for the constant temperature equipment of the oil bath heating system adopts a dual power automatic switching device. Its main function is to automatically switch between the main and backup working power supplies. When a common power supply failure occurs, it automatically switches to the backup power supply. When both power supplies are normal, the common power supply is working and the backup power supply is in standby mode.
The programmable controller (PLC) is the control of the execution part of the air cooler control device, which receives various status signals from the transformer to control the execution part.? When the transformer of the oil bath heating constant temperature system is put into operation, the main cooler is put into operation, that is, the working group cooler is running. The auxiliary cooler is controlled based on the oil surface temperature, winding temperature, load signal, etc. of the transformer, and can be started as follows.
The power of the entire system of the constant temperature equipment in the oil bath heating system is provided by the compressor. The compressor is equivalent to moving a physical object from a low potential position to a high potential position. In the system, its purpose is to compress low-temperature gas into high-temperature gas through the compressor, and then the gas exchanges heat with other media in the heat exchanger. So the quality of the compressor will directly affect the refrigeration effect of the entire oil bath heating constant temperature system.
The function of the constant temperature equipment condenser in the oil bath heating system is to cool the high-temperature and high-pressure refrigerant superheated steam discharged by the compressor into a liquid or gas-liquid mixture. The heat released by the refrigerant in the condenser is carried away by the cooling medium (water or air), and the liquid low-temperature refrigerant is easily evaporated at low pressure, converted into steam, and absorbs the heat of the cooled medium to achieve refrigeration purposes.
관련 권장 사항
-
초고온 소재 냉온 충격 박스 냉장 오일
1230초고온 재료 충격 시험 챔버 테스트 장치의 증발기에 오일이 너무 많이 얼어 냉각이 불충분하고 냉각이 느려질 수 있습니다. 초고온 재료의 증발기에 저장된 오일은 ...
세부 정보 보기 -
Method for controlling shutdown of water cooled chiller of single reaction kettle
1348The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it i...
세부 정보 보기 -
냉각기의 성에를 어떻게 처리하나요?
1293냉각기에는 여러 종류가 있으며이 작품에 익숙한 고객은 확실히 냉각기에 익숙합니다. 냉각기의 프로스팅에 대해 많은 사람들이 무지한데, 그럼 LNEYA와 함께 자세히 알아 보겠습니다! 1. 냉각기 인 경우 ...
세부 정보 보기 -
다양한 고온 및 저온 사이클 기계 산업의 컴프레서에 대한 설명
1262In the pharmaceutical and chemical industry, the application of high and low temperature cycle machine is relatively common. LNEYA high and low temperature cycle machine compressors use Emerson, Taikang, Duling and other brand compressors, but the...
세부 정보 보기