Method for controlling shutdown of water cooled chiller of single reaction kettle
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
Related recommendations
-
How to choose low temperature and high temperature aging test equipment?
2234The refrigeration capacity and temperature range of materials in different industries are different. Generally speaking, the cooling capacity is divided into 80kw, 120kw, 180kw, 240kw, 360kw, and the cooling temperature ranges from -25°C to -5°C. ...
View details -
Analysis of Advantages and Disadvantages of Screw Water Chiller
2557Compared with other types of chillers, the overall energy consumption of high-quality screw water chiller is relatively small. Because the production technology of screw water chiller is more advanced and less energy is used, the equipment can qui...
View details -
Temperature sensor for ultra-low temperature refrigerator
2270Ultra-low temperature refrigerators are used in refrigeration equipment. They are generally used in refrigeration equipment below -60 ° C. They are used under some special conditions under low temperature conditions. Temperature control is very im...
View details -
Simulation analysis and result analysis of battery pack thermal management
2098battery pack thermal management simulation analysis
View details
LNEYA Thermo Refrigeration Co.,Ltd