500리터 용량의 냉난방 온도 제어 장비에 대한 요구 사항은 무엇인가요?

The 500-liter reaction kettle cooling and heating temperature control equipment is a dynamic temperature control system, a fully closed circulation pipeline, which can be automatically heated or cooled according to the process requirements.
1. A series of exothermic and endothermic reactions will occur during the polymerization reaction of the 500-liter reactor with cooling, heating and temperature-controlling equipment.
2. It can control one or more reactors at the same time. It is a large system device with integrated temperature control, which can be produced according to the requirements of working conditions.
3. During the chemical reaction, it is recommended that the surrounding operators do not get too close to avoid some troubles. During the reaction process, if the heat is not removed in time, the reaction pressure will be affected. If the pressure is too high, the whole reaction will be in some danger.
4. When selecting, it needs to be selected according to the size, weight, type of the reactor and the volume of the jacket or coil. The heat ratio and viscosity of the materials in the reactor are closely related.
5. The size of the jacket or coil needs to be calculated to estimate the time required for temperature control. Users can customize whether explosion-proof or isolation is required according to their needs.
6. It can be equipped with reactors of different volumes for refrigeration, heating and temperature control. Since reactors of different sizes bring different heat capacities, their endothermic or exothermic capacities are also different.
7. Parameter configuration After the user provides the manufacturer with accurate operating data, the corresponding cooling and heating temperature control scheme will be provided after calculation, and the corresponding cooling and heating control scheme will be provided after calculation. In the scheme, the specific model and parameter configuration will be selected, and the user can see the brand of each accessory in the parameter configuration.
8. Improper selection of the model will slightly affect the running time of the equipment, resulting in an increase in the cost of use, and in severe cases, the equipment will not be able to run and use.
Therefore, the 500-liter reactor cooling and temperature control equipment needs to provide accurate working conditions such as reactor size, temperature requirements, materials, etc., so as to avoid the selection of large or small equipment that cannot meet the expected temperature requirements.
관련 권장 사항
-
Application of supporting experimental equipment for refrigeration and heating system
1260The mixing tank with jacket and insulation layer is a three-layer insulation mixing tank with heating function, which has the functions of heating, insulation, mixing, etc. It is widely used in dairy, chemical, food, beverage, pharmaceutical, phar...
세부 정보 보기 -
Ultra Low Temp Freezer DW of LNEYA
1716Ultra Low Temp Freezer DW Description: Ultra-low temperature freezer mainly used for scientific research, special materials of low-temperature test and preservation; freezing of red blood cells, white blood cells, skin, bacteria, semen, biological...
세부 정보 보기 -
What is the principle of industrial air-cooled chillers
1634Many industrial productions are inseparablefrom the low-temperature production environment provided by the chiller andcannot obtain efficient production capacity. Therefore, industrial chillerequipment is a very important refrigeration equipmen...
세부 정보 보기 -
고온 및 저온 급격한 온도 변화 테스트 챔버 공통 결함
1088고온 및 저온 급격한 온도 변화 테스트 챔버의 고온 테스트에서 온도 변화가 테스트 온도 값에 도달하지 않으면이 경우 전기 시스템을 검사하고 결함을 제거 할 수 있습니다 ...
세부 정보 보기