Hot and cold rapid temperature change test chamber common fault
In the high-temperature test of the hot and cold rapid temperature change test chamber, once the temperature change does not reach the test temperature value, in this case, the electrical system can be inspected and the faults can be eliminated one by one. If the temperature rises very slowly, it is necessary to check the air circulation system to see if the regulating baffle of the wind cycle is normal. On the contrary, check whether the motor of the wind cycle is running normally. If the temperature is too high, you need to set the PID setting parameters. If the temperature rises directly and the temperature is over-protected, the controller fails and the control instrument must be replaced.
If the cold and hot rapid temperature change test chamber does not reach the test index during the operation, it is necessary to observe whether the temperature change is very slow, or the temperature has a rising trend after the temperature reaches a certain value. The former must check First, do the drying of the working chamber before the low temperature test, keep the studio dry and then put the test sample into the working room and then test it. If the test sample in the working room is too much, the wind in the working room cannot be fully circulated. After eliminating the above reasons, it is necessary to consider whether it is a fault in the refrigeration system, so it is necessary to ask the professional of the manufacturer for maintenance. The latter phenomenon is caused by the poor use of the equipment. The ambient temperature at which the equipment is placed and the position where it is placed (the distance between the back of the cabinet and the wall) must meet the requirements.
In the hot and cold rapid temperature change test chamber, if the actual humidity will reach a high point or the actual humidity will differ greatly from the target humidity, it may be caused by the drying of the gauze on the wet bulb sensor. Then check the sink of the wet bulb sensor. Whether there is water shortage in the water, the water level in the water tank is automatically controlled by a water level controller. Check whether the water supply system of the water level controller is normal and the water level controller works normally. Another possibility is that the wet gauze is hardened due to the long use time or the purity of the water supply, so that the gauze becomes hard and the gauze can not absorb moisture and is dry. The above phenomenon can be eliminated by replacing or cleaning the gauze. The latter phenomenon is mainly because the humidification system does not work. Check the water supply system of the humidification system, whether there is a certain amount of water in the water supply system, whether the water level control of the humidification boiler water level is normal, and whether the water level in the humidification boiler is normal. If everything above is normal, then check the electrical control system, which should be repaired by professional maintenance personnel.
The failure of the hot and cold rapid temperature change test chamber needs to be solved in time to avoid the impact of some faults and cause equipment damage.
Related recommendations
-
Industry and introduction of low temperature chiller
1900In petroleum refining, petrochemical industry, organic synthesis, chemical products and other industrial production, refrigeration technology must be applied to control the reaction temperature during processes such as liquefaction, condensation, ...
View details -
What are the system components of various distillation devices?
16101. A complete set of short-path distillation equipment: including short-path evaporator, heating system, feeding system, cooling system, vacuum system, material collection unit, etc.; 2. A complete set of thin film distillation equipment: includin...
View details -
What are the causes of the blockage of the cooler?
1977The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical conn...
View details -
Prospects for the development of electronic test thermal systems
1858For the modern society, energy conservation and emission reduction is also an important task. In the development of semiconductor, chip, integrated circuit and other industries, the electronic test thermal system can effectively test its temperatu...
View details
LNEYA Thermo Refrigeration Co.,Ltd