How to maintain the high and low temperature cooling constant temperature system?
The high and low temperature cooling constant temperature system performs refrigeration and heating operation in the pharmaceutical and chemical industry. It follows the rules of operation and meticulous requirements to continuously improve its quality. Its reliability and practicality play a decisive role in the quality of users.

When users operate the high and low temperature cooling and constant temperature system, they need special personnel for professional management and maintenance, and qualified units should send special personnel to the supplier’s factory for training and learning from time to time to obtain professional maintenance and repair experience and capabilities. The condenser is fixed every three months. For high and low temperature cooling and constant temperature system compressors using air-cooled cooling, the condensing fan should be regularly overhauled and the condenser should be decontaminated and dust-removed to ensure good ventilation and heat exchange performance.
For high and low temperature cooling and constant temperature system compressors using water cooling, in addition to ensuring the inlet water pressure and inlet water temperature, the corresponding flow rate must be ensured, and the inside of the condenser must be cleaned and descaled regularly to obtain its continuous heat exchange. performance.
The high and low temperature cooling and constant temperature system also needs to clean the evaporator regularly. Under the forced air circulation, a lot of dust and small particles will condense on the evaporator, so it must be cleaned regularly. There is also waterway and humidifier cleaning. If the waterway is not unblocked and the humidifier becomes fouled, it will cause the humidifier to dry out and damage the humidifier. Therefore, the waterway and humidifier must be cleaned regularly.
It is also necessary to insist on setting the temperature near the ambient temperature after each test, and then cut off the power after working for about 30 minutes, and then wipe the inner wall of the working chamber. When the product is out of service for a long time, the product should be energized regularly every half a month, and the energization time should not be less than 1 hour.
Because the price of high and low temperature cooling and constant temperature system is basically composed of multiple electrical, refrigeration and mechanical systems. Therefore, once there is a problem with the equipment, it is necessary to conduct a comprehensive inspection and comprehensive analysis of the entire equipment system. Generally speaking, the process of analysis and judgment can be from outside to inside, that is, after removing the external factors, the fundamental failure phenomenon can systematically decompose the equipment.
The quality requirements of the high and low temperature cooling and constant temperature system are relatively high. The user needs to customize a certain maintenance plan in peacetime, and must not blindly disassemble or replace parts, so as to avoid unnecessary trouble.
관련 권장 사항
-
How to solve the common faults of industrial circulating chillers?
1086For industrial circulating chillers, if they are always in a high-temperature operating state, a large amount of cold air will be seriously lost. After ensuring the sealing effect of the use environment, effective thermal insulation can be carried...
세부 정보 보기 -
저온 냉각기의 부품 분석
1199The low temperature chiller is a cooling water equipment which is widely used. So, when using it, you should first understand the principle of the cryogenic water chiller and its accessories, so as to run the cryogenic water chiller more efficient...
세부 정보 보기 -
열전달 오일 순환 시스템 냉각 성능 저하 문제
1365나는 많은 사용자가 오랜 시간 사용 후 열전달 오일 순환 시스템을 접한 후 장면의 열화를 느낄 것이라고 믿으며, 이러한 현상이 발생하면 모든 사람에게 상기시키기 위해 전문 제조업체로서 LNEYA, 사용자 ...
세부 정보 보기 -
고온 및 저온 액체 순환 냉각기의 얼음 막힘을 해결하기 위한 작은 쿠데타
855In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams. In the pip...
세부 정보 보기