Small coup to deal with ice blockage of high and low temperature liquid circulating chillers
In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams.
In the pipeline of the high and low temperature liquid circulating chiller, if ice blockage occurs, it is recommended to replace the damaged pipe section and repair the missing spot welding first, and redo and tighten the loose threaded joint. In order to ensure that there is no leakage in the high-pressure test of the high and low temperature liquid circulating water chiller pipeline. The high and low temperature liquid cycle chiller refrigeration cycle system pipeline is divided into high pressure section and low pressure section, flushed with four-recording carbon, and purged with nitrogen to seal for later use.
At the same time, the high and low temperature liquid circulating chiller compressor unit must be strictly processed in accordance with the steps, replacing the new filter of the high and low temperature liquid circulating water chiller, and then blown and sealed for use. The high and low temperature liquid circulating chiller refrigeration cycle system pipeline is unsealed and the compressor unit is quickly assembled After that, perform quantitative charging of the refrigerant, and wait for five minutes (waiting for the static equilibrium of the pressure in the high-pressure zone and low-pressure zone in the refrigeration cycle system pipeline) to power on and test the machine.
When the user usually faces the operation of high and low temperature liquid circulating chillers, they need to pay attention to moisture prevention and seal or seal the parts of the high and low temperature liquid circulating water coolers that are not being repaired. Maintenance is carried out in rainy weather.
However, there is always a case in case. For high and low temperature liquid circulating chillers with slight ice blockage after maintenance, the refrigerant can be recovered, replaced with new filters, or connected in series with a large cubic freezer filter at the high-pressure exhaust end, or even Refill the refrigerant quantitatively.
There are one or two ways to face the phenomenon of ice blockage in high and low temperature liquid circulating chillers. If the user does not know how to solve it, do not solve it blindly by himself. It is recommended to find a professional maintenance person to solve it.
Related recommendations
-
Combination of heater and chiller for melting mixing process
1806In the process of molten mixing, the combination of heater and cooler is used to achieve precise temperature control of the mixed materials to meet specific process requirements. This type of combination equipment is commonly used in industries su...
View details -
Application of Screw Water Chiller
1849The power of screw water chiller is relatively larger than that of scroll chiller. It is mainly used in central air conditioning system or large industrial refrigeration. It can be divided into two categories. 1.Twin-screw refrigeration compressor...
View details -
What is the temperature control method of the reactor?
1871The reaction kettle used for temperature control has a large capacity and a thick wall, so it is a controlled object with a large heat capacity and a long pure lag time. As the reaction progresses, the heat transfer coefficient of each heat transf...
View details -
You Know What Technical Problems You Need to Know before You Buy A Low Temperature Chamber
1804Question 1: Is the temperature change rate of temperature impact test the faster the better? Explanation: Is the temperature change rate faster and better in the temperature impact test? Does the temperature change rate have any effect on the tes...
View details
LNEYA Thermo Refrigeration Co.,Ltd