냉매 알람이 없는 완전 밀폐형 냉난방 온도 조절기에 대한 솔루션
What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle of the lack of refrigerant alarm, it can be solved very well. Today I will share two points with you so that everyone will encounter this problem. It can be solved very quickly.

When we encounter a refrigerant shortage alarm in a fully enclosed heating and cooling thermostat, the first thing we have to do is to check to see if the liquid level on the expansion tank of the fully enclosed heating and cooling thermostat is at the normal level, if it expands at this time The liquid level of the fuel tank is lower than the low level, then this alarm is caused by the lack of oil in the system. What we need to do is to add new heat transfer oil in time until the system has a stable pressure and the liquid level of the expansion tank is at the normal level. It can be solved.
There is another situation that will also cause the fully enclosed heating and cooling thermostat to alarm for lack of refrigerant. That is, an alarm occurs after a period of use. At this time, we also need to check the liquid level of the expansion tank. If the heat transfer oil is lower than the low level, there must be a leak in the pipeline, which needs to be found and repaired in time. If it is not the leakage problem, then Most of it should be that the liquid level float switch of the expansion oil tank touches the wall of the expansion oil tank, causing the liquid level switch to not work normally. At this time, we need to remove the liquid level switch and re-reinforce it. The main reason for this situation may be due to The fully enclosed heating and cooling thermostat is caused by slight vibration during use.
The above are two solutions for the lack of refrigerant alarm. The alarm is a fully enclosed heating and cooling thermostat’s built-in protection, mainly to prevent the heating tube from burning dry, so when we encounter this problem, we can solve it in most cases according to the two methods shared by the editor. If it is solved No way to contact LNEYA after-sales technical support.
관련 권장 사항
-
산업용 재순환 냉각기의 구조적 특성
928화학 반응에는 반응 온도에 대한 엄격한 요구 사항이 있습니다. 화학 반응을 원활하게 수행하려면 온도를 적절한 온도로 높여야 합니다. 반응 후, 다시 온도는 ...
세부 정보 보기 -
반도체 수냉식 온도 제어 플랫폼의 스로틀 구성 요소
1228반도체 수냉식 온도 제어 플랫폼의 스로틀링 구성 요소는 냉동 시스템에 없어서는 안 될 네 가지 주요 구성 요소 중 하나입니다. 그 기능은 고압 액체 컴프레서의 압력을 낮추는 것입니다.
세부 정보 보기 -
What is the principle of industrial air-cooled chillers
1635Many industrial productions are inseparablefrom the low-temperature production environment provided by the chiller andcannot obtain efficient production capacity. Therefore, industrial chillerequipment is a very important refrigeration equipmen...
세부 정보 보기 -
How to Choose Water Chiller Units in Small Factories
1187Professional water chiller factory said that the quality of equipment can be seen from the three main components of small water chiller units. The most important one is the compressor, which is the heart of the unit and the most critical component...
세부 정보 보기