As a industrial temperature control device,
industrial water chiller is often in 24-hour operation. Therefore, it is very
important to choose a industrial chiller with good performance. Wuxi Guanya
Refrigeration Technology Co., Ltd. specializes in the manufacturing, research,
development, production and sales of industrial temperature control equipment
such as industrial water chiller and ultra-low temperature chiller. 15 years of
concentration and experience have made LNEYA’s industrial water chiller a
leader in the industry. LNEYA specializes in providing customers with cooling
and heating temperature control solutions, and meets customers’ temperature
needs with superior performance industrial water chiller. In order to maximize
the service life of the industrial water chiller, we need to know the following
installation and maintenance methods in daily use.
Installation precautions: the installation
site of the industrial water chiller must be the floor or installation mat, and
can bear the operating weight of the chiller. It should be placed in a machine
room with a room temperature of 4.4~43.3℃, and sufficient space shall be
reserved around and above the industrial water chiller for daily maintenance.
When the water source and the surrounding environment of the cooling water
tower are bad, the cooling water circuit must be equipped with a Y-type filter
and cleaned regularly. Choose the matching cooling tower according to the
refrigeration capacity of the industrial water chiller. After the chilled water
piping system passes the leak test, it is necessary to wrap the insulation
layer to avoid cooling loss and dripping of the pipeline.
Maintenance method: If the industrial water
chiller has been used for more than 6 months, and refrigeration capacity is
reduced, please arrange staff to clean the radiator. If the industrial water
chiller is equipped with a pressure gauge, check whether the pressure of the
high pressure gauge is higher than 300PSI. If it exceeds, please clean the
radiator or check whether the water hose has been fully opened. The repair is
carried out according to the above operation for several times, but the alarm
signal of industrial water chiller failure is still ringing, please arrange
staff to repair it. After the chiller is out of service for a period of time,
the water pump blade may be solidified due to the water dirt. When starting up
again, the water pump rotor must be loosened first to avoid that the pump blade
does not rotate and burn the motor.
관련 권장 사항
-
LNEYA electric car motor circulating cooling system lubricant description
1216Electric vehicle motor circulating cooling system is used in new energy vehicle battery testing. So the performance requirements are very high. Among them, the lubricating oil of the electric vehicle motor circulating cooling system has a certain ...
세부 정보 보기 -
-
How To Choose The Screw Type Water-Cooled Chiller
1312Compared with the similar chillers, the screw type water-cooled chiller has many advantages. We as one of the top chiller manufacturers share you more. 1. The temperature of the heat conducting liquid can be adjusted to any temperature you want, a...
세부 정보 보기 -
소형 온도 제어 시스템 장비 용접 유지보수 주의사항
1180소형 서모 스탯 제어 시스템 장비는 수리시 비교 지점에주의를 기울이고, LNEYA 전문 제조업체는 용접 부분도 유지 보수의 핵심 포인트 중 하나라고 상기시킨 다음 어떤 측면에주의를 기울여야하는지 상기 시켰습니다 ...
세부 정보 보기