배터리 팩 테스트 온도 시뮬레이션 냉각기의 유지 관리 및 유지 보수

배터리 팩 테스트 온도 시뮬레이션 냉각기는 기업에서 점점 더 널리 사용되고 있지만 후속 유지 관리 및 유지 보수도 더 중요합니다. 다음은 몇 가지 유지 관리 및 유지 보수 방법에 대한 간략한 소개입니다. 1....
1. The temperature of the battery pack that does not need to be opened is not closed before the start-up to simulate the water inlet valve of the condenser on the chiller, resulting in water leakage. Part of the cooling return water flows away from the condenser of the non-starting unit, reducing the cooling water flow in the condenser of the operating unit, causing the condensation pressure to rise, the operating current of the main engine to increase, and the cooling capacity of the unit to decrease. Stopping the operation not only wastes electricity, but also reduces the cooling effect, and is easy to damage the equipment.
2. Before starting up, close the water inlet valve of the condenser of the unit that does not need to be operated to prevent water leakage. Open the water inlet and outlet valves on the condenser of the unit to be operated (generally the outlet valve is normally open, the water inlet valve is opened and closed according to needs. The condenser and the evaporator are the same) and turn on the corresponding cooling water pump to adjust the water inlet and outlet pressure of the condenser.
3. If the pointer of the pressure gauge of the water inlet and outlet of the condenser swings too much, it means that there is air in the equipment system, and the air needs to be exhausted to continue to the next step after the pressure gauge indicates normal.
4. It adopts an intelligent main control board, and the LED display is stable and durable, with multiple settings and fault display functions; it is equipped with a water outlet pressure gauge, which is convenient for observing pressure and flow.
관련 권장 사항
-
Troubleshooting of refrigeration system failure of material aging test equipment at low temperature
1128Regular maintenance work for the material low temperature and high temperature aging test system, and troubleshooting of the refrigeration system is also very important. Here are a few tips. 1. Exhaust at double high pressure, heat dissipation ma...
세부 정보 보기 -
Solution to the inability to cool down the industrial high and low temperature recirculating chiller
1205When the high and low temperaturerecirculation chiller system is in use, what is the general cause if the hightemperature cannot be reduced? How should we deal with such failures?First, let’s analyze theprinciple and method of cooling. The circ...
세부 정보 보기 -
LNEYA low temperature chiller selection classification description
1344Different enterprises and different industries have different requirements for the low-temperature chiller of Wuxi Guanya (LNEYA). The choice of models is also different, so it is better to understand them in the selection. The low temperature chi...
세부 정보 보기 -
Analysis of Common Faults in New Energy Vehicle Power Battery Test System
993If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the b...
세부 정보 보기