Precautions for customers installing Lneya’s cryogenic industrial chillers
One. When installing low-temperature industrial chillers, you need to pay attention to some installation requirements.
1. The cryogenic industrial chiller should be installed directly in a horizontal position, do not install it upside down or diagonally
2. Low-temperature industrial refrigerators generate heat during operation, and should ensure the circulation of cooling air. There should be a certain space around the installation. The generated heat is emitted upwards, so do not install it around heat-resistant equipment.
3. Freezers for low-temperature industry cannot be installed in places with various fiber paper sheets and metal fragments.
The water outlet of the cryogenic industrial chiller should be connected to the water inlet of the supporting instrument, and the water outlet of the instrument should be connected to the water inlet of the cooling circulating water machine.
Second, open the low-temperature industrial chiller, you can see the wiring terminals, do not connect the wrong wire when wiring. (Only high-power low-temperature industrial chillers have power connections)
1. The power supply must be connected to the main wire terminal. If the power supply is connected to other wire terminals by mistake, it will destroy the cryogenic industrial refrigerator. In addition, confirm whether the power supply voltage is within the allowable voltage range;
2. The ground terminal must be well grounded to prevent electric shock or fire accident;
3. Be sure to connect the terminal and the wire with a crimp terminal to ensure the reliability of the connection;
4. After completing the circuit connection, please check whether the connection is correct;
5. With or without wiring;
6. Is there a short circuit between the arrows and the connecting wire or short circuit to ground;
7. If the use temperature is below 5 degrees, please add antifreeze to the circulating fluid.
Low-temperature industrial chillers must be grounded, otherwise electric shock or fire accidents may occur. Wiring should be performed by professionals. Start the work after confirming that the power is off (OFF), otherwise an electric shock may occur.
Three. Operation of cryogenic industrial chillers
1. Check whether the check wiring is correct before starting the operation;
2. Whether the connecting water pipeline is correct and firm;
3. Confirm whether the water tank is filled with water.
Cryogenic industrial chillers are widely used and have certain applications in the pharmaceutical, chemical, petroleum and other industries. In use, you need to know their use knowledge in time to avoid problems.
관련 권장 사항
-
Various reactors and materials use PLC temperature control system
1303The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
세부 정보 보기 -
대형 냉장 및 가열 서큘레이터와 테스트 챔버의 차이점
9491. 특수한 상황에서 고온 테스트의 경우 고온 및 저온 테스트 챔버가 요구 사항을 충족하지 못할 수 있습니다. 일반적으로 고온 및 저온 테스트 상자의 고온 상한은 200 ℃이며 그 ...
세부 정보 보기 -
Liquid Cooled Battery Pack BMS Test Cooling Water Circulator
1307As the temperature gradually increases, the use of the cooling water circulator for the BMS test of the liquid-cooled battery pack also gradually peaks. The rated power of the cooling water circulator for BMS testing of liquid-cooled battery packs...
세부 정보 보기 -
공장 보일러 작동에 대한 오해
949보일러는 공장에서 매우 흔한 장비입니다. 많은 사람들이 보일러에 대해 오해하고 있다고 LNEYA Xiaobian은 말합니다. 오해 1 증기 압력이 높을수록 좋습니다. 보일러 증기 압력의 선택은 주로 ...
세부 정보 보기