Misunderstanding about the operation of the factory boiler
The boiler is a very common equipment in the factory. LNEYA Xiaobian tells everyone that many people have misunderstandings about it.
Misunderstanding 1 The higher the steam pressure, the better.
The choice of boiler steam pressure depends mainly on the needs of the user. The steam pressure is low, the safety of the pressure-bearing parts is favorable, the energy consumption is also low, and the steam pressure is too high, the energy consumption is high, the corresponding steam equipment, the piping system and the valve are also subjected to high pressure, and the maintenance requirements are also higher. Therefore, the furnace worker must operate in accordance with the specified working steam pressure, generally allowing the fluctuation of the steam pressure to be 0.05 to 0.15 MPa.
Misunderstanding 2 The higher the pot water level, the safer it is.
If the water level is too high, the steam humidity is increased, and the steam quality is poor, it will endanger the use of steam equipment and production.
Misunderstanding 3 The more fuel is added, the better
The weight ratio of coal to air is preferably 1:9.14. When the amount of air is constant and the amount of fuel is excessive, a large amount of incomplete combustion products such as carbon monoxide are generated in the furnace.
Misunderstanding 4 The finer the coal particles, the better
From the burning point of view, the finer the coal particles, the easier it is to form a good mixture with the air, and the more complete the combustion. However, LNEYA Xiaobian told everyone that the coal particles are too fine, and the power consumption of the milling power will be greatly increased for the power station boiler.
Misunderstanding 5, the faster the grate travels, the better
As is known to all, the boiler load is large, and the fuel supply amount must be increased accordingly. At this time, the coal gate door has been fully opened, and the travel speed of the grate should be accelerated. However, when the demand for heat load is not large, when the air volume is constant, the grate travels too fast, the furnace will be deficient in oxygen, the flame will become yellow, dark, unstable, and heat loss will increase. Therefore, when the coal particles, humidity, ash are too large and the coal seam is too thick, it is forbidden to put in a higher grate speed.
Misunderstanding 6 The more the fire, the better
Fire setting is a common manual method for industrial boilers. By setting the fire, the fire can be eliminated, the fire can be reduced and the hearth of the furnace can be leveled, and the combustion is uniform and strong. However, excessive fires will reduce the overall thermal efficiency. This is because when the fire is set, a large amount of cold air is entered into the furnace, and the average temperature of the flame in the furnace section is lowered.
Misunderstanding 7 The greater the negative pressure of the furnace, the better
The negative pressure of the coal-fired furnace furnace should be maintained at 10-20 Pa. Excessive negative pressure will result in:
1 furnace leakage increases, and exhaust heat loss increases;
2 fan power consumption increased;
3 fly ash increases the wear on the heated surface along the path;
4 reduce the thermal efficiency of furnace combustion.
Misunderstanding 8 Sewage time is better
LNEYA Xiaobian told everyone that the sewage discharge time is too long, one wastes a lot of heat, which affects the heating steam pressure; the second is unfavorable to the boiler water circulation, and in serious cases, the water wall tube blasting will occur. Therefore, regular sewage discharge must be carried out in accordance with the principle of “diligent discharge, less discharge, and uniform discharge”. Generally, it is required to discharge at least once every eight hours, and the time for each discharge should not exceed 30s. It is strictly forbidden to time out.
Misunderstanding 9 The higher the oil level, the better
There are many rotating machinery in the boiler auxiliary machine, and its normal oil level plays an extremely important role in its service life. Some operators have trouble-saving and excessive oil injection. They believe that high oil level operation will result in better lubrication and cooling effects. The general oil level should be 2/3~1/2 of the height of the oil mark. If the oil level is too high, the fuel tank will heat up, the oil leakage will increase, and the mechanical failure will increase.
All of the above are the knowledge that must be understood when using the boilers for everyone.
Related recommendations
-
Analysis of the work and industry application of the chiller
2132Although there are many different types of chillers, most use the same cooling principle. An important part of the process is the coolant or refrigerant, which holds more heat than water and helps maintain an efficient cooling process. Heat is rem...
View details -
Which reactions need temperature control in the process of chemical and pharmaceutical production?
2282Precise temperature control plays a crucial role in the reaction process during synthesis/crystallization in the production of chemical and pharmaceutical products. In the field of fine chemicals, many chemical reaction processes and crystallizati...
View details -
What are the maintenance of glycol chillers in daily operation?
2264In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance. Refrig...
View details -
Selection of heat transfer oil for the refrigeration and heating system of the reactor
2342In the chemical industry, the reactor is a commonly used container, and temperature control is the main quantity to be controlled. The heating and refrigeration cycle equipment of the reactor is an important factor to ensure product quality. The r...
View details
LNEYA Thermo Refrigeration Co.,Ltd