What Will Happen to the Over-Cooling of the Low Temperature Chiller?
As we all know, the 저온 냉각기 is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the lowest temperature of the 저온 냉각기 can only reach – 40 degrees. The main reason is limited by the limit operating conditions of single-stage piston compressor. If the evaporator temperature of the chiller is too low, the following problems will arise when it exceeds the limit operating conditions.
만약 저온 냉각기 is excessively refrigerated, it will have a great impact on the use function of the 저온 냉각기 product itself. The actual compression process deviates from the equal compression process to a great extent. The compressor gas transmission coefficient of the chiller decreases, and the compressor gas transmission capacity will be greatly reduced. This is very disadvantageous to the service life of the 저온 냉각기 products.
If the 저온 냉각기 is over-refrigerated for a long time, the influence on the compressor inside the 저온 냉각기 can not be ignored. When the compressor is over refrigerated, the exhaust temperature of the compressor is too high, and the lubricating oil on the cylinder surface of the compressor becomes thinner, which makes the lubricating condition worse. It may even cause the carbonization of lubricating oil, the phenomenon of cylinder pulling and the improper sealing of valve plates.
관련 권장 사항
-
What should I pay attention to when replacing a water-cooled chiller compressor
1059Once the compressor of the water-cooledchiller fails, the compressor needs to be replaced in time, but the replacementof the compressor is not as simple as imagined.Before the water-cooled chiller compressoris replaced, the reasons for the dama...
세부 정보 보기 -
냉각기의 냉매를 보관할 때 주의해야 할 점은 무엇인가요? 수락 사항은 무엇입니까?
1009Refrigerant is an essential substance to make the chiller have refrigeration effect, which has great potential safety hazards in the use process. Refrigerant, also called refrigerant, refrigerant carrier and snow seed, is used in different equipm...
세부 정보 보기 -
Leakage Detection Tips of Low Temperature Freezer
1211Pressure leaking detectionIt is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The le...
세부 정보 보기 -
김이 나는 시스템 온도 제어 안전 요구 사항
1190김이 나는 시스템 온도 제어는 우시 구아냐 엘네야에서 설계하고 생산한 저온 냉장고 중 하나입니다. 온도 범위는 -5°C에서 -150°C입니다. 2 차 과냉각 기술이 채택되고 냉동은 ...
세부 정보 보기