50p 냉동고 압축기의 프로스팅 현상을 해결하는 방법은 무엇입니까?
50p 냉동고는 산업용 저온 처리에 사용되지만 성능이 좋지 않으면 산업 작업으로 이어질 수 있으며 특히 결함이있는 경우 해결하기가 더 어렵습니다. 따라서 50p 냉동기의 다양한 결함을 이해하는 것이 좋습니다.
50p freezer compressor return air frosting is a very common phenomenon in the refrigeration system. Under normal conditions, system problems will not be formed immediately, and the fine frosting will not be treated normally. If the frosting phenomenon is serious, it needs to be solved in time. The root cause of this situation is that the refrigerant flowing through the evaporator does not fully absorb the heat required to expand itself to a predetermined pressure temperature value.
The temperature and pressure volume values that cause the 50p freezer to return to the air are relatively low. This problem may be caused by the evaporator not being able to absorb heat normally, or the cold volume generated by the evaporator cannot be taken away. The representation is that the return liquid temperature and pressure are normal or slightly lower, and the compressor is gradually condensed toward the evaporator from the gas return port. After a long time, all the ice is frozen from the compressor return port to the evaporator and the throttle valve to the evaporator section. , there is a low pressure. Since the amount of refrigerant is too small, the evaporation pressure of the evaporator is low, resulting in low evaporation temperature, which will gradually lead to condensation of the evaporator to form a heat insulation layer and transfer the expansion point to the compressor return air to cause the compressor to return to the air. If the amount of fluorine is normal or excessive, and if there is a situation such as excessive condensation heat exchange, the high pressure is low, then the refrigerant at the front end of the throttle valve under the same volume will show low pressure and high quality.
At the initial throttle opening, the quality of the refrigerant liquid flowing through the throttle valve will be more than normal, and the amount of heat that needs to be absorbed from the evaporator will be excessive. If the corresponding heat is not completely absorbed from the evaporator, the compressor will be returned. The tracheal temperature is low. At the same time, due to the low pressure at the front end of the throttle valve, the back pressure of the throttle valve will also be low. If the Dalian 50p chiller installation system is an expansion valve, (detecting the return pipe temperature and pressure, the pipe temperature is reduced, The pressure reduction opening increases) Compared with the normal state opening, it will not make too much adjustment, then the low pressure will be maintained until the compressor returns to the frost, which seems to be deficient in fluorine (low pressure and low pressure) and low return pipe temperature. Causes frosting.
In operation, users must also recognize the benefits of high-performance 50p freezer for work operation. LNEYA uses high-profile branded accessories to operate equipment more efficiently.

관련 권장 사항
-
난방 및 냉방 시스템용 액세서리 및 액세서리
1220냉난방 시스템의 선택은 매우 중요하며 가격과 온도 조절뿐만 아니라 품질도 고려해야 합니다. 또한 난방 및 냉방 시스템의 액세서리에도주의를 기울여야합니다. F...
세부 정보 보기 -
Laboratory dedicated chiller pressure description
1090The laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chil...
세부 정보 보기 -
How to replace the four-way valve of the chilled water machine?
1142The four-way valve of the chilled water machine needs to be replaced in time after a long period of use, so how to replace it? You can look at the suggestions. When replacing the chilled water machine, you need to remove the connecting pipe conne...
세부 정보 보기 -
실험실 탈이온수 냉각기는 어떻게 선택하나요?
1212순수한 물은 일반적으로 불순물, 이온, 유기물 등을 제거하도록 처리된 물을 말합니다. 일반적인 예로는 증류수, 역삼투압수, 탈이온수 등이 있습니다. 탈이온수는 전도도가 낮기 때문에 ...