Laboratory dedicated chiller pressure description
The laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chiller.
The reference value of the test chamber-specific chiller and the pressure resistance of the piping system components refers to the design given pressure related to the mechanical strength of the pipeline components. The nominal pressure is generally expressed by PN. Nominal pressure—the compressive strength of the product at the reference temperature, expressed in PN, unit: MPa, reference temperature: different materials, the reference temperature is also different, for example, the steel reference temperature is 250 ° C, the nominal pressure is 1.0 Mpa, Recorded as: PN 1.0 Mpa.
The working pressure of the special chiller in the laboratory refers to the large pressure specified by the high working temperature of the pipeline conveying medium for the operation safety of the pipeline system. The working pressure is generally expressed by Pt.

The design chiller design pressure of the laboratory refers to the large instantaneous pressure of the water supply pipe system acting on the inner wall of the pipe. The sum of the working pressure and the residual water hammer pressure is generally used. The design pressure is generally expressed by Pe. The test pressure refers to the pressure to be achieved by the pipeline, container or equipment under the pressure resistance and air tightness test. The test pressure is generally expressed by Ps.
The nominal chiller pressure of the laboratory is a nominal pressure artificially specified for the convenience of design, manufacture and use. The unit of this nominal pressure is actually the pressure, and the pressure is the common name of Chinese. The unit is “Pa”. Not “N”. The nominal pressure of a pressure vessel refers to the nominal pressure of the pressure vessel flange. The nominal pressure of the pressure vessel flange is generally divided into seven grades, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40 MPa.
In general, the pressure can be divided into: test pressure > nominal pressure > design pressure > working pressure, so, everyone understands?
관련 권장 사항
-
Disadvantages and advantages of general heat transfer oil heating circulation system
1108열전도 오일 가열 순환기는 완전히 폐쇄 루프 구조를 채택하여 가열 된 매체에 열 에너지에 직접 작용하며 장점은 다음과 같습니다: (1) 열 전달 표면의 지속적인 갱신으로 인해 열 손실이 적습니다. (2) ...
세부 정보 보기 -
공냉식 극저온 냉각기 선택에 대한 설명
1278Many users struggle with the problems of air-cooled cryogenic chillers and water cooled cryogenic chillers. However, enterprises should make choices according to their actual environment. For this reason, Wuxi Guanya professional manufacturer has ...
세부 정보 보기 -
Why does a chiller need to be installed for cooling the water storage tank?
1039The main reasons for configuring a chiller for cooling the water storage tank are related to the following aspects: Temperature Control: In many industrial and commercial applications, such as air conditioning systems, chemical processes, ...
세부 정보 보기 -
공정 엔지니어링에서 동적 온도 제어 시스템의 온도 제어
948화학 산업, 특히 공정 엔지니어링에서는 많은 공정이 온도에 묶여 있거나 특정 온도 제어 애플리케이션에 의해 지원될 수 있으므로 효율성이 높아집니다. 후자의 예로는 연속 온도 제어가 있습니다.
세부 정보 보기