Laboratory dedicated chiller pressure description
The laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chiller.
The reference value of the test chamber-specific chiller and the pressure resistance of the piping system components refers to the design given pressure related to the mechanical strength of the pipeline components. The nominal pressure is generally expressed by PN. Nominal pressure—the compressive strength of the product at the reference temperature, expressed in PN, unit: MPa, reference temperature: different materials, the reference temperature is also different, for example, the steel reference temperature is 250 ° C, the nominal pressure is 1.0 Mpa, Recorded as: PN 1.0 Mpa.
The working pressure of the special chiller in the laboratory refers to the large pressure specified by the high working temperature of the pipeline conveying medium for the operation safety of the pipeline system. The working pressure is generally expressed by Pt.
The design chiller design pressure of the laboratory refers to the large instantaneous pressure of the water supply pipe system acting on the inner wall of the pipe. The sum of the working pressure and the residual water hammer pressure is generally used. The design pressure is generally expressed by Pe. The test pressure refers to the pressure to be achieved by the pipeline, container or equipment under the pressure resistance and air tightness test. The test pressure is generally expressed by Ps.
The nominal chiller pressure of the laboratory is a nominal pressure artificially specified for the convenience of design, manufacture and use. The unit of this nominal pressure is actually the pressure, and the pressure is the common name of Chinese. The unit is “Pa”. Not “N”. The nominal pressure of a pressure vessel refers to the nominal pressure of the pressure vessel flange. The nominal pressure of the pressure vessel flange is generally divided into seven grades, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40 MPa.
In general, the pressure can be divided into: test pressure > nominal pressure > design pressure > working pressure, so, everyone understands?
Related recommendations
-
What Will Happen to the Over-Cooling of the Low Temperature Chiller?
1973As we all know, the low temperature chiller is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the l...
View details -
From what aspects should we consider the use of circulating coolers?
1842Circulating coolers are a popular choice for temperature-critical applications because they provide stable temperature control, constant flow and constant pressure control. Many process heating systems require cooling and heating. For example, man...
View details -
Application and function of explosion-proof constant temperature circulation system
2054Temperature control in drug research and development and chemical experiments, as well as temperature control in small-scale experimental production and industrial production, all require highly dynamic constant temperature controllers. The chemic...
View details -
Details of the temperature control system of the isolated reactor
2145The temperature control system of the isolated reactor adopts the heat-conducting medium to perform dynamic temperature control of fluid cooling and heating, and to control the cooling and heating of the heat-conducting medium or the reaction mate...
View details
LNEYA Thermo Refrigeration Co.,Ltd