Effect of evaporator on refrigeration system in special instrument for low temperature experiment
The low temperature experiment special instrument is LNEYA’s refrigeration heating equipment for the laboratory. The importance of the evaporator is self-evident. So what effect does the evaporator have on the refrigeration system?
According to different models, the choice of evaporators for low-temperature experiment special instruments is also different, such as box-type low temperature experiment special instruments, using water tank coil evaporator; open low temperature experiment special instrument and screw type refrigerator, then choose Shell and tube evaporator; for special instruments for acid and alkali resistance low temperature experiments, titanium tube evaporator or stainless steel plate exchanger can be selected. An ice water machine can have a variety of options, of course, can be customized according to user needs.
The temperature condition of the evaporator of the low-temperature experiment special instrument: under normal circumstances, the outer surface of the evaporator is very cold, and the condensation water droplets are continuously dripped, and the temperature of the inlet and outlet air is relatively large, usually Δt can be 12~14 ° C. The surface of the evaporator is not too cool, there is not much dew, or condensation, and the sound of the refrigerant flow is very loud, and the temperature difference between the inlet and outlet is small. The reason is that the refrigerant amount is insufficient, or the expansion valve opening degree is small.

The factors affecting the evaporation temperature of special instruments for low temperature experiments are as follows:
Evaporator pipe oiling: Under normal circumstances, due to the mutual solubility of lubricating oil and refrigerant, oil film will not form on the surface of the heat exchanger, and the thermal resistance of the oil film may be disregarded. However, in the case of additional lubricating oil, it must be the same as the original one. Lubricating oil to prevent the formation of oil film. Air filter plugging: The filter must be replaced regularly to ensure the required air circulation for the air conditioner. Dry filter plugging: In order to ensure the normal circulation of the cooling enthalpy, the refrigeration system must be kept clean and dry. If the system has impurities, the drying filter will be blocked, the system will be difficult to supply liquid, and the cooling effect will be affected. Too little refrigerant, additional refrigerant.
The evaporator of the low-temperature experiment special instrument also has certain requirements in terms of quality. The brand has a certain quality guarantee, so that the operation will be more stable.
관련 권장 사항
-
충격 시험기 모델의 스크롤 압축기를 교체하는 방법은 무엇인가요?
1532다른 충격 테스터 모델에 따라 구성도 다소 다릅니다. 그중에서도 스크롤을 교체할 때 특히 주의해야 하는 것은 컴프레서입니다. 교체가 발견되지 않으면 충격 테스터를 사용할 수 없습니다.
세부 정보 보기 -
Classification and Application of Industrial Water Chillers
1272In lots ofindustrial production processes, it is difficult to obtain high efficientindustrial production efficiency if there is no industrial water chiller toprovide a low temperature production environment. Therefore, industrial water chill...
세부 정보 보기 -
What is the temperature control method of the reactor?
936The reaction kettle used for temperature control has a large capacity and a thick wall, so it is a controlled object with a large heat capacity and a long pure lag time. As the reaction progresses, the heat transfer coefficient of each heat transf...
세부 정보 보기 -
Fully closed cycle high viscosity fluid refrigeration heating flow control system
955Application:1. The tested object is connected to a test platform adapter.2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and co...
세부 정보 보기