How to replace the scroll compressor of the impact tester model?
In terms of different impact tester models, the configuration is also somewhat different. Among them, special care should be taken when replacing the scroll is a compressor. If the replacement is not noticed, the impact tester cannot be used.
The prohibition of the impact tester is only carried out from the high pressure side when the scroll compressor is replaced. If it is only carried out from the high pressure side, the axial seal of the scroll will cause the refrigerant to remain on the low pressure side. This is to carry out the simultaneous discharge of the high-pressure side and the low-pressure side when the refrigerant is discharged, and when the maintenance impact tester replaces the scroll compressor. Things to be aware of. When repairing the impact tester welding operation, sufficient nitrogen gas is introduced into the equipment to prevent the formation of an oxide film on the inner wall of the copper pipe (the time for nitrogen to pass is sufficient). To check the nitrogen content, a ignited scent or cigarette can be placed at the other inlet of the nitrogen. If the scent is extinguished, the air in the system is emptied and the welding operation can be performed.
In order to prevent the impact tester from burning the compressor during the test, a vacuum pump must be used to evacuate. Moreover, it is forbidden to use the compressor as a vacuum pump to evacuate the air in the external pipe when replacing the compressor or other parts. The maintenance impact tester has higher requirements due to the use of the scroll compressor. Reminder: When the maintenance impact tester system is in the maintenance, it is forbidden to reduce the pressure in the system to a vacuum state. Only the pressure in the system can be cooked above the gauge pressure of 0.03MP, otherwise the compressor will draw the side vortex. The axial seal of the disc forms a vacuum, which can damage the compressor if not handled properly.
The difference between the compressors of different impact tester models is definitely present. If the operator cannot replace them completely, it is recommended to contact the manufacturer for replacement.
Related recommendations
-
How to choose the right hot and cold circulator?
2016The hot and cold circulator is widely used in the pharmaceutical and chemical industry to provide users with hot and cold controlled, uniform temperature and constant temperature. It can also be directly equipped with reactors, reactors, etc. fo...
View details -
High and low temperature device related instrument maintenance instructions
2031The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
View details -
Description of working principle of high and low temperature impact test chamber
2155Spot high and low temperature impact test chamber, also known as three-box high and low temperature impact test chamber, high and low temperature impact test chamber is mainly composed of low temperature storage chamber, high temperature storage c...
View details -
Equipment attention points of laboratory high and low temperature cycle equipment manufacturers
2132In the laboratory, a wide range of experimental instruments are widely used. When the experimental instruments are in operation, they are inseparable from the high-low temperature circulating device refrigeration heating equipment. What should be ...
View details
LNEYA Thermo Refrigeration Co.,Ltd