How to replace the scroll compressor of the impact tester model?
In terms of different impact tester models, the configuration is also somewhat different. Among them, special care should be taken when replacing the scroll is a compressor. If the replacement is not noticed, the impact tester cannot be used.
The prohibition of the impact tester is only carried out from the high pressure side when the scroll compressor is replaced. If it is only carried out from the high pressure side, the axial seal of the scroll will cause the refrigerant to remain on the low pressure side. This is to carry out the simultaneous discharge of the high-pressure side and the low-pressure side when the refrigerant is discharged, and when the maintenance impact tester replaces the scroll compressor. Things to be aware of. When repairing the impact tester welding operation, sufficient nitrogen gas is introduced into the equipment to prevent the formation of an oxide film on the inner wall of the copper pipe (the time for nitrogen to pass is sufficient). To check the nitrogen content, a ignited scent or cigarette can be placed at the other inlet of the nitrogen. If the scent is extinguished, the air in the system is emptied and the welding operation can be performed.
In order to prevent the impact tester from burning the compressor during the test, a vacuum pump must be used to evacuate. Moreover, it is forbidden to use the compressor as a vacuum pump to evacuate the air in the external pipe when replacing the compressor or other parts. The maintenance impact tester has higher requirements due to the use of the scroll compressor. Reminder: When the maintenance impact tester system is in the maintenance, it is forbidden to reduce the pressure in the system to a vacuum state. Only the pressure in the system can be cooked above the gauge pressure of 0.03MP, otherwise the compressor will draw the side vortex. The axial seal of the disc forms a vacuum, which can damage the compressor if not handled properly.
The difference between the compressors of different impact tester models is definitely present. If the operator cannot replace them completely, it is recommended to contact the manufacturer for replacement.
Related recommendations
-
New product recommendation-small desktop circulating chiller FL-800N
2365In recent years, with the rapid development of the pharmaceutical industry, the pharmaceutical equipment industry has also developed rapidly. To this end, Lneya launched the small desktop circulating chiller FL-800N, which is welcomed by the marke...
View details -
LNEYA dynamic temperature control system description
2953The long-term research of LNEYA state temperature control system has been extended to the pharmaceutical chemical industry for a long time. The dynamic temperature control system is safe after-sales service, and it is strictly tested before leavin...
View details -
LNEYA fights against “NCP” and resumes production safely
2529The NCP casts a haze over the new year of 2020, but the moment when everything recovers will never be absent. At present, for many enterprises across the country, their operating pressure and shoulder responsibility are very heavy. However, LNEYA ...
View details -
Minimum 40 degree refrigerator use precautions
2241The temperature of the lower 40 degree refrigerator is indoor temperature: 5-32 °C, relative humidity 80%/22 °C, the distance from the ground > 10cm, the altitude below 2000m, the safe environment guarantees a smoother operation of the lower 40...
View details
LNEYA Thermo Refrigeration Co.,Ltd