LNEYA 냉각기의 원리
산업용 냉각기는 일반적으로 사출 성형, 공구 및 다이 커팅, 식음료, 화학, 레이저, 공작 기계, 반도체 등 다양한 응용 분야의 제품 및 기계를 냉각하는 데 사용됩니다. 대부분의 경우...
In most process cooling applications, the pumping system circulates cold water or water/glycol solution from the chiller to the process. This cooled fluid removes heat from the process and the warm fluid returns to the cooler. Process water is a means of transferring heat from the process to the cooler.
The process cooler contains a compound called a refrigerant. There are many types of refrigerants and applications depending on the temperature required, but they are all based on the fundamental principle of compression and phase change of the refrigerant from liquid to gas and back to liquid. This process of heating and cooling the refrigerant and changing it from a gas to a liquid and returning again is a refrigeration cycle.

The refrigeration cycle begins with a low pressure liquid/gas mixture entering the evaporator. In the evaporator, heat from the process water or water/glycol solution causes the refrigerant to boil and the refrigerant to change from a low pressure liquid to a low pressure gas. The low pressure gas enters the compressor where it is compressed into a high pressure gas. The high pressure gas enters the condenser, and the ambient air or condenser water removes heat and cools it into a high pressure liquid. The high pressure liquid moves to the expansion valve, controlling the amount of liquid refrigerant entering the evaporator, including restarting the refrigeration cycle.
LNEYA air-cooled cooling equipment uses ambient air to cool and condense hot refrigerant gas back into the liquid. It can be located inside the cooler or can be remotely located outside, but in the end it will block the heat from the cooler to the air. In a water-cooled condenser, water from the cooling tower cools and condenses the refrigerant.
관련 권장 사항
-
How To Vacuum The Ultra-Low Temperature Freezer Refrigeration System?
1094LNEYA ultra-low temperature freezer indoor and outdoor connection has been completed, observe the oil pump oil mark indication to see if there is enough oil, and then start the vacuum pump to see if it is normal. Then unscrew the large valve back ...
세부 정보 보기 -
LNEYA 초저온 냉동 순환기의 주요 유지 관리 포인트
1155초저온 냉장 순환기는 장기간 사용 후 유지 관리가 필요한데, 어떤 부분에 주의를 기울여야 하나요? 초저온 냉동 순환기를 제때 점검하고 유지 관리하십시오. 문제를 찾을 수 있습니다 ...
세부 정보 보기 -
How to troubleshoot the failure of the material aging test chiller?
1104Regular maintenance work for the material aging test chiller, and troubleshooting is also very important. 1. Exhaust at double high pressure, heat dissipation may be problematic. When it is detected that the high and low pressure of the system are...
세부 정보 보기 -
Theory of Ice Flow, Ice Water Quality, Flow and Pressure of Ice Water Machine
900The softening of water is also an important problem in the process of using chillers.The pH value of water also needs to be continuously observed. The optimum pH value should be equal to 7. The pH value greater than 7 will cause terrible corrosion...
세부 정보 보기