LNEYA 초저온 냉동 순환기의 주요 유지 관리 포인트
Ultra-low temperature refrigeration circulators need to be maintained after a long period of operation, so what aspects should be paid attention to?

Check and maintain the ultra-low temperature refrigeration circulator on time. It can find problems such as pipe blockage, foreign matter, impurities, etc., and can plan the cleaning and finishing operations of radiating water pipes, cooling water towers, and cooling water filling operations of cooling water towers for ultra-low temperature cooling. Long-term and stable operation of the circulator.
The circuit system of the ultra-low temperature refrigeration circulator also needs to be checked and maintained, and the problem should be solved as soon as possible, otherwise it will cause greater problems. The check should be based on the basic voltage and current, the electric resources need to be increased and so on, and then check whether the components are working normally, whether they are normal, etc.
Regular inspection and maintenance:
Even if the LNEYA ultra-low temperature refrigeration circulator is not in operation for a long time, it should be checked and maintained, and the operation should be started on time to avoid unavoidable problems such as oxidation of the water pump, compressor and related components due to prolonged non-operation.
Check and maintain the ultra-low temperature refrigeration circulator on time to find the problem early: avoid excessive wear of the components. Severe wear of components may cause the machine to stop. For example, the rotor, bearing, piston, etc. of the screw compressor have fixed wear. Checking on time helps to find the problem in time and deal with it in time. Once the check interval is too long or there is no regular maintenance, ultra-low temperature cooling The compressor of the circulator may not be repaired and will be directly obsolete.
Regular inspection and maintenance—fan system or water cooling system can ensure the heat dissipation function of the ultra-low temperature refrigeration circulator itself and normal operation.
Regarding refrigerant, check and maintain the machine on time to find out the leakage and lack of refrigerant in time. After the leakage is found, the leakage point should be found in time to correct or replace the valve. If the refrigerant is found to be missing, it should be refilled in time to avoid impact Normal refrigeration effect of ultra-low temperature refrigeration circulator.
To sum up
Generally speaking, if the ultra-low temperature refrigeration circulator is found to be faulty, it needs to be solved in time to avoid greater product problems. In addition, maintenance and inspection work is also necessary.
관련 권장 사항
-
급격한 온도 변화 테스트 챔버 온도 제어 지침
1140급격한 온도 변화 테스트 챔버의 습도 범위 선택은 습도 지수 또는 이슬점 온도 다음에 해당 온도 범위를 표시해야한다는 점에 유의해야합니다. 상대 습도 때문에 ...
세부 정보 보기 -
글리콜 냉각기 누출 검사 시 주의사항
1634글리콜 칠러의 누출 점검에 대한 주요 사항글리콜 칠러를 작동하는 동안 냉동 시스템이 누출되지 않는 것이 중요합니다. 글리콜 칠러에서 냉매 및 기타 가스의 누출을 방지하기 위해 ...
세부 정보 보기 -
영하 30℃에서 에틸렌 글리콜 냉각기의 설정 및 작동에 대한 소개
1020영하 30도 에틸렌 글리콜 냉각기는 컴프레서 냉방을 사용하는 단일 유체 저온 냉동 장치입니다. 사용자가 작동할 때 어떻게 설정해야 하나요? 1. 자동 로그 아웃 시간 자동 로그 아웃은 사용자가 ...
세부 정보 보기 -
극저온 공정 냉각 시스템을 사용하여 총 카나비노이드를 추출하는 효율적인 방법
1222Although cannabis plants have been used for medicinal purposes for thousands of years, modern science has identified steroids, flavonoids and more than 100 therapeutically active compounds known as cannabinoids. Due to the significant synergy betw...
세부 정보 보기