저온 냉장 수조에서 흔히 발생하는 디버깅 문제는 무엇인가요?
When the low-temperature cooling bath is in debugging, if the local cooling effect is not good, the system may be blocked by foreign matter or the system design is unreasonable and cannot be adjusted normally. At this time, LNEYA removes foreign matter and thoroughly cleans it to adjust the slope of the pipeline.
When debugging, it is found that the vibration and noise of the pump are large when it is running. It may be that the axial and radial deviation of the coupling is large. It may be that the pump flange is too large and the anchor bolts are unevenly stressed. It is the natural vibration frequency of the pump and the pipeline that cause resonance. At this time, the axial and radial deviation of the coupling are adjusted quickly. Adjust the natural vibration frequency between the pump and the pipe, install the relevant soft joint parts, replace the flange and make the anchor bolts evenly.
During commissioning, it was found that the cooling capacity could not reach the required fixed value. It may be that the cooling tower water temperature did not reach the specified cooling parameter, or the pump output was insufficient, or the condenser isolation gasket was misplaced and could not be cooled, or the pipeline in the condenser was blocked. Repair the cooling tower to meet the water temperature and water requirements, remove foreign matter in the pipeline, and check if the condenser isolation gasket is misaligned.

If the exhaust pressure is too high, it is necessary to pay attention to whether the cooling water is insufficient, whether the condensation in the condenser heat transfer tube is serious, whether the cooling water temperature is too high, whether there is too much air in the system, check the cause, repair the cooling tower, and heat transfer of the condenser. The tube is cleaned to remove air from the system.
If severe frost formation is found, check if the return air filter is clogged, if the exhaust air volume is loose after the fan belt is loose, and if the return air valve is too small, it is recommended to clean the return air filter and adjust the fan belt. Adjust the size of the return air valve.
Common faults encountered in the commissioning of these low-temperature refrigeration baths, we try to check them before debugging, try to avoid these faults.
관련 권장 사항
-
급격한 온도 변화 테스트 챔버를 위한 전기 부품 선택
1183급격한 온도 변화 테스트 챔버의 전기를 설치하고 디버깅하는 방법은 무엇입니까? 전원 분배를 위해 다음 방법을 참조하고 전원 공급 장치의 용량에주의를 기울이고 여러 전자 장치에 단일 전원 공급 장치를 사용하지 마십시오.
세부 정보 보기 -
Discrimination of power battery integration test system
1488Using the degree of superheat to judge whether the opening degree of the integrated test system of the power battery is appropriate, and using a thermometer to measure the difference between the temperature of the return pipe and the evaporating t...
세부 정보 보기 -
The influence of the evaporator of the semiconductor thermostat on the refrigeration effect
988Different models of semiconductor thermostat equipment have different options for evaporation. According to different models, the choice of evaporator is different. For example, box-type semiconductor thermostat equipment uses water tank coil type...
세부 정보 보기 -
Compressor key protection of reactor temperature control system
1326In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor. Under normal working conditions, the compressor of the temper...
세부 정보 보기